Adhesive precoated bracket systems and operator coated bracket systems: Is there any difference? A systematic review and meta-analysis.

Ahmed Mohamed Alakttash, Mohamed Fawzi, David Bearn.   

Abstract

OBJECTIVES: To investigate whether adhesive precoated brackets (APC) are more efficient than operator-coated brackets (OPC) regarding failure rate, bonding time, patient experience, gingival health, plaque accumulation, and white spot lesion formation.
MATERIALS AND METHODS: Five online databases: Cochrane Central Register of Controlled Trials (CENTRAL), Scopus, PubMed, MEDLINE, and Web of Science were searched for potential eligible randomized controlled trials (RCTs). A Google Scholar and gray literature search was undertaken. References of included studies were screened for potential eligible studies. Results were collated from each database and modified Cochrane data extraction forms were completed. Quality assessment was performed using Cochrane RoB 2.0 tool for RCTs.
RESULTS: Five studies met the inclusion criteria. All reported failure rates using metal brackets for both APC and OPC systems except one that compared clear APC to clear OPC. Three studies reported bonding time differences between the bracket systems. A quantitative synthesis of four studies reporting failure and three reporting bonding time was undertaken. Random effect meta-analysis determined there were no statistically significant differences in bond failures between bracket systems with an odds ratio of 0.890 (P = .808). Bonding time showed a statistically significant (P = .01) but not clinically significant shorter bonding time with OPC. There was insufficient evidence to assess plaque accumulation, gingival health, and either patient or operator experience.
CONCLUSIONS: There is no superiority of either bracket system regarding failure rate. OPC are statistically significantly superior over APC in bonding time although this is most likely not clinically significant.

Entities:  

Keywords:  Adhesive precoated brackets; Operator coated brackets; Pre-coated brackets

Mesh:

Substances:

Year:  2018        PMID: 30556748      PMCID: PMC8117688          DOI: 10.2319/051818-373.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  9 in total

1.  Clinical bond failure of pre-coated and operator-coated orthodontic brackets.

Authors:  K Kula; R Schreiner; J Brown; A Glaros
Journal:  Orthod Craniofac Res       Date:  2002-08       Impact factor: 1.826

2.  A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces.

Authors:  M G BUONOCORE
Journal:  J Dent Res       Date:  1955-12       Impact factor: 6.116

3.  Clinical comparison of an adhesive precoated vs. an uncoated ceramic bracket system.

Authors:  A Verstrynge; A Ghesquiere; G Willems
Journal:  Orthod Craniofac Res       Date:  2004-02       Impact factor: 1.826

4.  Clinical performance of orthodontic brackets and adhesive systems: a randomized clinical trial.

Authors:  S Sunna; W P Rock
Journal:  Br J Orthod       Date:  1998-11

5.  Adhesive pre-coated brackets, a comparative clinical study.

Authors:  S Ash; N Hay
Journal:  Br J Orthod       Date:  1996-11

6.  Epoxy adhesives for orthodontic attachments: progress report.

Authors:  G V Newman
Journal:  Am J Orthod       Date:  1965-12

7.  Ex vivo bond strength of adhesive precoated metallic and ceramic brackets.

Authors:  D R Bearn; J C Aird; J F McCabe
Journal:  Br J Orthod       Date:  1995-08

8.  A prospective randomized clinical trial to compare pre-coated and non-pre-coated brackets.

Authors:  M Wong; S Power
Journal:  J Orthod       Date:  2003-06

9.  An evaluation of a fluoride-releasing, visible light-activated bonding system for orthodontic bracket placement.

Authors:  A L Sonis; W Snell
Journal:  Am J Orthod Dentofacial Orthop       Date:  1989-04       Impact factor: 2.650

  9 in total
  1 in total

1.  Comparison of flash-free and conventional bonding systems: A systematic review and meta-analysis.

Authors:  He Wang; Ge Feng; Bo Hu; Haonan Tian; Yunchun Kuang; Tingwei Zhang; Jinlin Song
Journal:  Angle Orthod       Date:  2022-07-14       Impact factor: 2.684

  1 in total