Literature DB >> 9878638

A comparison of two antimicrobial-impregnated central venous catheters. Catheter Study Group.

R O Darouiche1, I I Raad, S O Heard, J I Thornby, O C Wenker, A Gabrielli, J Berg, N Khardori, H Hanna, R Hachem, R L Harris, G Mayhall.   

Abstract

BACKGROUND: The use of central venous catheters impregnated with either minocycline and rifampin or chlorhexidine and silver sulfadiazine reduces the rates of catheter colonization and catheter-related bloodstream infection as compared with the use of unimpregnated catheters. We compared the rates of catheter colonization and catheter-related bloodstream infection associated with these two kinds of antiinfective catheters.
METHODS: We conducted a prospective, randomized clinical trial in 12 university-affiliated hospitals. High-risk adult patients in whom central venous catheters were expected to remain in place for three or more days were randomly assigned to undergo insertion of polyurethane, triple-lumen catheters impregnated with either minocycline and rifampin (on both the luminal and external surfaces) or chlorhexidine and silver sulfadiazine (on only the external surface). After their removal, the tips and subcutaneous segments of the catheters were cultured by both the roll-plate and the sonication methods. Peripheral-blood cultures were obtained if clinically indicated.
RESULTS: Of 865 catheters inserted, 738 (85 percent) produced culture results that could be evaluated. The clinical characteristics of the patients and the risk factors for infection were similar in the two groups. Catheters impregnated with minocycline and rifampin were 1/3 as likely to be colonized as catheters impregnated with chlorhexidine and silver sulfadiazine (28 of 356 catheters [7.9 percent] vs. 87 of 382 [22.8 percent], P<0.001), and catheter-related bloodstream infection was 1/12 as likely in catheters impregnated with minocycline and rifampin (1 of 356 [0.3 percent], vs. 13 of 382 [3.4 percent] for those impregnated with chlorhexidine and silver sulfadiazine; P<0.002).
CONCLUSIONS: The use of central venous catheters impregnated with minocycline and rifampin is associated with a lower rate of infection than the use of catheters impregnated with chlorhexidine and silver sulfadiazine.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9878638     DOI: 10.1056/NEJM199901073400101

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  104 in total

1.  Catheter-Related Bloodstream Infection.

Authors: 
Journal:  Curr Infect Dis Rep       Date:  1999-08       Impact factor: 3.725

Review 2.  Drug resistance in intensive care units.

Authors:  W C Albrich; M Angstwurm; L Bader; R Gärtner
Journal:  Infection       Date:  1999       Impact factor: 3.553

3.  Nosocomial Infections in the Intensive Care Unit Associated with Invasive Medical Devices.

Authors:  Nasia Safdar; Christopher J. Crnich; Dennis G. Maki
Journal:  Curr Infect Dis Rep       Date:  2001-12       Impact factor: 3.725

4.  Antimicrobial activity of prosthetic heart valve sewing cuffs coated with minocycline and rifampin.

Authors:  Rabih O Darouiche; Vance G Fowler; Karim Adal; Marcia Kielhofner; David Mansouri; L Barth Reller
Journal:  Antimicrob Agents Chemother       Date:  2002-02       Impact factor: 5.191

5.  The search for value in health care: a review of the National Committee for Quality Assurance efforts.

Authors:  Andrea Ohldin; Adrienne Mims
Journal:  J Natl Med Assoc       Date:  2002-05       Impact factor: 1.798

Review 6.  Diagnosis, prevention, and management of catheter related bloodstream infection during long term parenteral nutrition.

Authors:  D Hodge; J W L Puntis
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-07       Impact factor: 5.747

7.  Intravenous therapy.

Authors:  C Waitt; P Waitt; M Pirmohamed
Journal:  Postgrad Med J       Date:  2004-01       Impact factor: 2.401

Review 8.  Catheter-associated infections: pathogenesis affects prevention.

Authors:  Barbara W Trautner; Rabih O Darouiche
Journal:  Arch Intern Med       Date:  2004-04-26

9.  In vitro potency and in vivo efficacy of a novel bis-indole antimicrobial compound in reducing catheter colonization.

Authors:  Mohammad D Mansouri; Timothy J Opperman; John D Williams; Charles Stager; Rabih O Darouiche
Journal:  Antimicrob Agents Chemother       Date:  2012-01-23       Impact factor: 5.191

10.  Prevention of catheter related bloodstream infection by silver iontophoretic central venous catheters: a randomised controlled trial.

Authors:  J J Bong; P Kite; M H Wilco; M J McMahon
Journal:  J Clin Pathol       Date:  2003-10       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.