Bladder shape impact on the accuracy of ultrasonic estimation of bladder volume.

L I Bih1, C C Ho, S J Tsai, Y C Lai, W Chow.   

Abstract

OBJECTIVE: Variations in bladder shape can lead to errors in ultrasonic estimation of the bladder volume. The purposes of this study were to compare the accuracies of various formulas to estimate bladder volume from sonographic measurements and to assess the impact of bladder shape on the accuracy of bladder volume estimation. STUDY
DESIGN: Twenty-four healthy volunteers (13 men, 11 women) and 55 spinal cord injury patients (48 men, 7 women) underwent ultrasonographic measurements of dimensions before and after voiding. Bladder shape was classified as cuboid, ellipsoid, or triangular prism. Ten formulas from the literature were applied to estimate bladder volume, using the volume voided or catheterized as the standard, and then linear regression was used to obtain optimal correction coefficients for the whole data set as well as each of the three bladder shapes.
SETTING: Rehabilitation hospital affiliated with a medical college.
RESULTS: The most accurate of the 10 formulas tested was height (H) X transverse depth (Dt) x weight (W) x 0.7 (mean error 17.4%+/-11.6%). Linear regression analysis yield optimal correction coefficients of .72 for the whole data set and .89, .81, and .66 for cuboidal, ellipsoid, and triangular prism-shaped bladders, respectively. The mean error for the estimation of bladder volume using .72 as the correction coefficient was 16.9%+/-11.9% and decreased to 12.7%+/-10.1% (p < .0001, paired t test) when the bladder shape was taken into account.
CONCLUSION: Using bladder shape for reference and applying the corresponding correction coefficient to volume calculations will improve the accuracy of the estimation.

Entities:  

Mesh:

Year:  1998        PMID: 9862299     DOI: 10.1016/s0003-9993(98)90419-1

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  9 in total

1.  Design and evaluation of an ultrasound-based bladder volume monitor.

Authors:  N K Kristiansen; J C Djurhuus; H Nygaard
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

2.  Feasibility of a novel 3-dimensional mathematical algorithmic computation of feline bladder volumes using point-of-care longitudinal and transverse cysto-colic ultrasonographic images.

Authors:  Xiu Ting Yiew; Samantha Clarke; Allan Willms; Shane W Bateman
Journal:  Can J Vet Res       Date:  2019-10       Impact factor: 1.310

3.  Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound.

Authors:  Anna S Nagle; Adam P Klausner; Jary Varghese; Rachel J Bernardo; Andrew F Colhoun; Robert W Barbee; Laura R Carucci; John E Speich
Journal:  J Biomech       Date:  2017-08-12       Impact factor: 2.712

4.  Accuracy of Measuring Bladder Volumes With Ultrasound and Bladder Scanning.

Authors:  Marilyn Schallom; Donna Prentice; Carrie Sona; Kara Vyers; Cassandra Arroyo; Brian Wessman; Enyo Ablordeppey
Journal:  Am J Crit Care       Date:  2020-11-01       Impact factor: 2.228

5.  Validation of 3-dimensional mathematical computation of feline bladder volume using orthogonal ultrasonographic bladder images.

Authors:  Chien Hsien Kitty Yang; Shane W Bateman; Xiu Ting Yiew; Allan R Willms
Journal:  Can J Vet Res       Date:  2022-07       Impact factor: 0.897

6.  Ultrasound-estimated bladder weight in healthy children.

Authors:  Boris Brkljacić; Andrea Cvitković Kuzmić; Romana Dmitrović
Journal:  Eur Radiol       Date:  2004-03-27       Impact factor: 5.315

7.  The impact of bladder shape on the ultrasonographic measurement of bladder volume in children.

Authors:  Andrea Cvitković Kuzmić; Boris Brkljacić; Davor Ivanković
Journal:  Pediatr Radiol       Date:  2003-06-12

8.  Evaluation of bladder shape using transabdominal ultrasound: Feasibility of a novel approach for the detection of involuntary detrusor contractions.

Authors:  Thomas Gray; Luned Phillips; Weiguang Li; Charlotte Buchanan; Patrick Campbell; Andrew Farkas; Shahram Abdi; Stephen Radley
Journal:  Ultrasound       Date:  2019-02-26

9.  Comparison of 2D and 3D ultrasound methods to measure serial bladder volumes during filling: Steps toward development of non-invasive ultrasound urodynamics.

Authors:  Anna S Nagle; Rachel J Bernardo; Jary Varghese; Laura R Carucci; Adam P Klausner; John E Speich
Journal:  Bladder (San Franc)       Date:  2018-01-04