Abstract

Ultrasonic bladder volume monitors have successfully been used in the diagnosis and treatment of various urological disorders. Ultrasonic bladder monitors have been developed but they have either been too bulky or too simple and inaccurate. A new, wearable ultrasonic bladder volume monitor has been designed for urological patients. The instrument consists of seven phased-array ultrasonic transducers ergonomically arranged in a circular pattern to optimise detection of the bladder walls perpendicular to the abdominal wall. A Bluetooth radio link was used to transmit data to a laptop computer, where the main signal processing was performed. After detection of bladder surface points, a three-dimensional convex hull representing the bladder was generated, and the volume was estimated. Accuracy, precision, drift over time, temperature dependency and dynamic performance were evaluated using ultrasound phantoms. Furthermore, the system was tested on one volunteer using magnetic resonance imaging (MRI) as reference. The apparatus showed no significant drift, systematic error or temperature effects. Percentage error during static volume measurements had a 95% central prediction interval of +/-7.5% and mean absolute percentage error of 2.9%. The dynamic performance analysis showed linearity in the analysed volume interval. The in vivo study showed a high degree of correlation (R2= 0.99) between the volume measured using MRI and that measured with the apparatus.

Entities:  

Mesh:

Year:  2004        PMID: 15587467     DOI: 10.1007/bf02345209

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  17 in total

1.  [Volumetry of the urinary bladder with implantable ultrasound sensors].

Authors:  J R Scheepe; S Bross; P Braun; C Seif; K Becker; X P Nguyen; P Alken; K P Jünemann; S Schumacher
Journal:  Urologe A       Date:  2000-05       Impact factor: 0.639

2.  MRI assessment of the influence of body position on the shape and position of the urinary bladder.

Authors:  Niels Kristian Kristiansen; Steffen Ringgaard; Hans Nygaard; Jens Christian Djurhuus
Journal:  Scand J Urol Nephrol       Date:  2004

3.  Accuracy of bladder volume determinations in children using a suprapubic ultrasonic bi-planar technique.

Authors:  P Williot; G A McLorie; R F Gilmour; B M Churchill
Journal:  J Urol       Date:  1989-04       Impact factor: 7.450

4.  Bladder volume measurement with electrical impedance analysis in spinal cord-injured patients.

Authors:  C T Kim; T A Linsenmeyer; H Kim; H Yoon
Journal:  Am J Phys Med Rehabil       Date:  1998 Nov-Dec       Impact factor: 2.159

5.  Bladder volume sensing by local distension measurement.

Authors:  R D Dreher; G W Timm; W E Bradley
Journal:  IEEE Trans Biomed Eng       Date:  1972-05       Impact factor: 4.538

6.  Bladder volume sensing by resistance measurement.

Authors:  F M Waltz; G W Timm; W E Bradley
Journal:  IEEE Trans Biomed Eng       Date:  1971-01       Impact factor: 4.538

7.  Accuracy and repeatability of bladder volume measurement using ultrasonic imaging.

Authors:  C J Griffiths; A Murray; P D Ramsden
Journal:  J Urol       Date:  1986-10       Impact factor: 7.450

8.  Clinical utility of a portable ultrasound device in intermittent catheterization.

Authors:  H A Anton; K Chambers; J Clifton; J Tasaka
Journal:  Arch Phys Med Rehabil       Date:  1998-02       Impact factor: 3.966

Review 9.  Design of a miniaturized ultrasonic bladder volume monitor and subsequent preliminary evaluation on 41 enuretic patients.

Authors:  P Petrican; M A Sawan
Journal:  IEEE Trans Rehabil Eng       Date:  1998-03

10.  Residual urine volumes in patients with spinal cord injury: measurement with a portable ultrasound instrument.

Authors:  D D Cardenas; E Kelly; J N Krieger; W H Chapman
Journal:  Arch Phys Med Rehabil       Date:  1988-07       Impact factor: 3.966

View more
  5 in total

Review 1.  Ambulatory urodynamic monitoring: state of the art and future directions.

Authors:  Benjamin Abelson; Steve Majerus; Daniel Sun; Bradley C Gill; Eboo Versi; Margot S Damaser
Journal:  Nat Rev Urol       Date:  2019-05       Impact factor: 14.432

Review 2.  A comprehensive survey on non-invasive wearable bladder volume monitoring systems.

Authors:  Morteza Zakeri Nasrabadi; Hamideh Tabibi; Mahsa Salmani; Mahdieh Torkashvand; Eisa Zarepour
Journal:  Med Biol Eng Comput       Date:  2021-07-14       Impact factor: 2.602

3.  Urinary bladder volume tracking using a Kalman filter.

Authors:  N K Kristiansen; S O Sjöström; H Nygaard
Journal:  Med Biol Eng Comput       Date:  2005-05       Impact factor: 2.602

4.  Supervised Learning Classifiers for Electrical Impedance-based Bladder State Detection.

Authors:  Eoghan Dunne; Adam Santorelli; Brian McGinley; Geraldine Leader; Martin O'Halloran; Emily Porter
Journal:  Sci Rep       Date:  2018-03-29       Impact factor: 4.379

Review 5.  Recent advances in urodynamics in women.

Authors:  Georgina Baines; Ana Sofia Da Silva; George Araklitis; Dudley Robinson; Linda Cardozo
Journal:  F1000Res       Date:  2020-06-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.