Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment.

Y Haïkel1, R Serfaty, P Wilson, J M Speisser, C Allemann.   

Abstract

The purpose of this study was to assess the mechanical properties--torsional moment, maximum angular deflection, maximum bending moment, and permanent angular deflection--of four brands of nickel-titanium (NiTi) endodontic file, and compare them with a conventional stainless-steel instrument, both in the presence and absence of sodium hypochlorite (NaOCl). NiTi instruments from four manufacturers were randomly selected and subjected to NaOCl treatment for 12 or 48 h, or not at all. The mechanical properties under test were then measured automatically by a digital torque memocouple. Torsional moment and maximum angular deflection indicate the resistance to torsional fracture of an instrument, maximum bending moment the stiffness of the instrument, and permanent angular deflection the strength of the base alloy. All instruments evaluated complied with or exceeded ADA/ANSI Specification No. 28, with the sole exception of the Maillefer ISO size 40 for torsional moment. JS Dental and McSpadden NiTi files were the most resistant to torsional fracture, but all NiTi files were inferior when compared with stainless-steel files from a previous study. However, NiTi files were superior in flexibility, and Maillefer and Brasseler instruments were the best of the instruments tested. NiTi files also had negligible permanent deformation angles. Furthermore, for all properties tested, NaOCl had no statistically significant effect.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9855823     DOI: 10.1016/S0099-2399(98)80163-5

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  Influence of axial movement on fatigue of ProFile Ni-Ti rotary instruments: an in vitro evaluation.

Authors:  Marie-Chantal Avoaka; Youssef Haïkel
Journal:  Bosn J Basic Med Sci       Date:  2010-05       Impact factor: 3.363

2.  Effect of NaOCl and EDTA Solutions on Topography of ESX, TruShape and ProTaper Gold NiTi Rotary Instruments - An Atomic Force Microscopic Study.

Authors:  Abhijit M Pallewar; Roopadevi Garlapati; Bolla Nagesh; Praveen Kumar Gali; Chukka Ram Sunil; Varri Sujana
Journal:  J Conserv Dent       Date:  2020-08-04

3.  Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization.

Authors:  S Shahi; H Mokhtari; S Rahimi; V Shiezadeh; H Ashasi; M Abdolrahimi; M Foroughreyhani
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

4.  Effect of sodium hypochlorite on conventional and heat-treated nickel-titanium endodontic rotary instruments - An in vitro study.

Authors:  Jack Han-Hsing Lin; Bekir Karabucak; Su-Min Lee
Journal:  J Dent Sci       Date:  2020-09-14       Impact factor: 2.080

5.  Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics.

Authors:  Wai-Sze Chan; Karan Gulati; Ove A Peters
Journal:  Bioact Mater       Date:  2022-09-27

6.  Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization.

Authors:  Üreyen Kaya Bulem; Ayse Diljin Kececi; Hilmi Egemen Guldas
Journal:  J Appl Oral Sci       Date:  2013 Nov-Dec       Impact factor: 2.698

7.  An analysis of cyclic fatigue resistance of reciprocating instruments in different canal curvatures after immersion in sodium hypochlorite and autoclaving: An in vitro study.

Authors:  C Champa; V Divya; A Srirekha; Rupali Karale; Ashwija Shetty; Pushpalatha Sadashiva
Journal:  J Conserv Dent       Date:  2017 May-Jun
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.