PURPOSE: Magnetic resonance (MR)-guided percutaneous vascular interventions have evolved to a practical possibility with the advent of open-configuration MR systems and real-time tracking techniques. The purpose of this study was to assess an MR-tracking percutaneous transluminal angioplasty (PTA) catheter with regard to its safety profile and functionality.
METHODS: Real-time, biplanar tracking of the PTA catheter was made possible by incorporating a small radiofrequency (RF) coil in the catheter tip and connecting it to a coaxial cable embedded in the catheter wall. To evaluate potentially hazardous thermal effects due to the incorporation of the coil, temperature measurements were performed within and around the coil under various scanning and tracking conditions at 1.5 Tesla (T). Catheter force transmission and balloon-burst pressure of the MR-tracking PTA catheter were compared with those of a standard PTA catheter. The dilatative capability of the angioplasty balloon was assessed in vitro as well as in vivo, in an isolated femoral artery segment in a swine.
RESULTS: The degree of heating at the RF coil was directly proportional to the power of the RF pulses. Heating was negligible with MR tracking, conventional spin-echo and low-flip gradient-echo sequences. Sequences with higher duty cycles, such as fast spin echo, produced harmful heating effects. Force transmission of the MR-tracking PTA catheter was slightly inferior to that of the standard PTA catheter, while balloon-burst pressures were similar to those of conventional catheters. The MR-tracking PTA catheter functioned well both in vitro and in vivo.
CONCLUSION: The in vivo use of an MR-tracking PTA catheter is safe under most scanning conditions.

Entities:  

Mesh:

Year:  1998        PMID: 9853147     DOI: 10.1007/s002709900288

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  12 in total

1.  RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI.

Authors:  Fabio Settecase; Steven W Hetts; Alastair J Martin; Timothy P L Roberts; Anthony F Bernhardt; Lee Evans; Vincent Malba; Maythem Saeed; Ronald L Arenson; Walter Kucharzyk; Mark W Wilson
Journal:  Acad Radiol       Date:  2010-11-13       Impact factor: 3.173

Review 2.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

Review 3.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

Review 4.  Advances in interventional cardiovascular MRI.

Authors:  Venkatesh K Raman; Robert J Lederman
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

Review 5.  13C imaging-a new diagnostic platform.

Authors:  Sven Månsson; Edvin Johansson; Peter Magnusson; Chun-Ming Chai; Georg Hansson; J Stefan Petersson; Freddy Ståhlberg; Klaes Golman
Journal:  Eur Radiol       Date:  2005-06-14       Impact factor: 5.315

Review 6.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

Review 7.  Metal-induced artifacts in MRI.

Authors:  Brian A Hargreaves; Pauline W Worters; Kim Butts Pauly; John M Pauly; Kevin M Koch; Garry E Gold
Journal:  AJR Am J Roentgenol       Date:  2011-09       Impact factor: 3.959

8.  Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures.

Authors:  Theresa Reiter; Daniel Gensler; Oliver Ritter; Ingo Weiss; Wolfgang Geistert; Ralf Kaufmann; Sabine Hoffmeister; Michael T Friedrich; Stefan Wintzheimer; Markus Düring; Peter Nordbeck; Peter M Jakob; Mark E Ladd; Harald H Quick; Wolfgang R Bauer
Journal:  J Cardiovasc Magn Reson       Date:  2012-02-01       Impact factor: 5.364

Review 9.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10

10.  Clinical and Radiological Safety of Retained Implantable Doppler Devices Used for Free Flap Monitoring.

Authors:  Lucas Kreutz-Rodrigues; Waleed Gibreel; Brian T Carlsen; Matthew A Frick; Samir Mardini; Karim Bakri
Journal:  Plast Surg (Oakv)       Date:  2021-04-27       Impact factor: 0.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.