Literature DB >> 9852409

Evaluation of in vivo and in vitro quality of apheresis-collected RBC stored for 42 days.

S Holme1, M D Elfath, P Whitley.   

Abstract

BACKGROUND AND OBJECTIVES: New technological developments make it possible to collect red blood cells (RBCs) by apheresis, which allows for better product consistency and has the potential for improved RBC quality. The purpose of these studies was to evaluate the quality and consistency of units of RBCs collected by apheresis using the MCS+(R) machine (Haemonetics Corp., Braintree, Mass., USA).
MATERIALS AND METHODS: Two studies were performed. In study 1 (n = 10), using containers and CP2D/AS-3 solutions from Medsep Corp. (Covina, Calif. USA), one-unit apheresis RBCs were compared to manually collected RBCs in a random crossover design. In study 2 (n = 12), 6 subjects had one unit collected, while the remaining 6 subjects had two units of RBCs collected with comparison to previously manually collected RBCs from the same donors. Haemonetics containers and solutions were used in study 2.
RESULTS: Low RBC volume variability was found for the apheresis collections with a standard deviation of only 6 ml difference between actual and target volumes. Combining the data from the two studies (n = 21 pairs), at 42 days of storage, the apheresis units showed slightly lower hemolysis (0.44+/-0.26 vs. 0.61+/-0.50%), lower supernatant potassium levels (50+/-3 vs. 53+/-3 mEq/l), and improved tolerance to osmotic shock (47+/-3 vs. 49+/-3%) as compared to manual units (p < 0.05). There was no statistically significant difference in RBC ATP (3.0+/-0.6 vs. 2.9+/-0.5 micromol/g Hb) or in 24-hour percent recoveries (81+/-6 for apheresis vs. 81+/-4% for apheresis red cells). Apheresis RBC quality was not affected by the manufacturer (Haemonetics vs. Medsep) of solutions and containers.
CONCLUSIONS: RBC units collected by apheresis demonstrated low variability in volume of RBC mass collected, and showed similar RBC properties as compared to manually collected RBCs after processing and after 42 days of storage.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9852409

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  5 in total

1.  Peroxiredoxin-2 recycling is inhibited during erythrocyte storage.

Authors:  Victoria M Harper; Joo Yeun Oh; Ryan Stapley; Marisa B Marques; Landon Wilson; Stephen Barnes; Chiao-Wang Sun; Tim Townes; Rakesh P Patel
Journal:  Antioxid Redox Signal       Date:  2014-11-10       Impact factor: 8.401

2.  Microparticles formed during storage of red blood cell units support thrombin generation.

Authors:  Beth A Bouchard; Thomas Orfeo; Hollis N Keith; Elizabeth M Lavoie; Matthew Gissel; Mark Fung; Kenneth G Mann
Journal:  J Trauma Acute Care Surg       Date:  2018-04       Impact factor: 3.313

3.  Red Blood Cells Derived from Whole Blood Treated with Riboflavin and UV Light Maintain Adequate Cell Quality through 21 Days of Storage.

Authors:  Lina Y Dimberg; Suzann K Doane; Susan Yonemura; Heather L Reddy; Nick Hovenga; E Jane Gosney; Melissa Tran; Shilo Wilkinson; Raymond P Goodrich; Susanne Marschner
Journal:  Transfus Med Hemother       Date:  2019-02-22       Impact factor: 3.747

Review 4.  Quality Assessment of Established and Emerging Blood Components for Transfusion.

Authors:  Jason P Acker; Denese C Marks; William P Sheffield
Journal:  J Blood Transfus       Date:  2016-12-14

5.  A Randomized Comparison of Hemoglobin Content-Based Versus Standard (Unit-Based) Red Blood Cell Transfusion Policy.

Authors:  Erden Atilla; Selami Koçak Toprak; Sinem Civriz Bozdağ; Pervin Topçuoğlu; Önder Arslan
Journal:  Turk J Haematol       Date:  2015-02-20       Impact factor: 1.831

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.