Literature DB >> 9848734

In vivo correlation between blood T2* and oxygen saturation.

D Li1, D J Waight, Y Wang.   

Abstract

The in vivo relationship between blood T2* and oxygen saturation was investigated. A wide range of blood oxygen saturation levels was created in pigs by altering the ventilation rate. Blood T2* was measured in vivo in the abdominal aorta and the inferior vena cava, corresponding to each oxygen saturation level. Our results indicate that it is possible to measure blood T2* in vivo reliably with an MR technique we previously proposed. Blood T2* correlates closely with oxygen saturation levels over a wide range, and the relationship between blood T2* measured in vivo and oxygen saturation can be approximated by a linear function.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9848734     DOI: 10.1002/jmri.1880080609

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  18 in total

Review 1.  Review of new techniques in echocardiography and magnetic resonance imaging as applied to patients with congenital heart disease.

Authors:  D J Sahn; G W Vick
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

2.  Intracranial dural arteriovenous fistula with retrograde cortical venous drainage: use of susceptibility-weighted imaging in combination with dynamic susceptibility contrast imaging.

Authors:  K Noguchi; N Kuwayama; M Kubo; Y Kamisaki; K Kameda; G Tomizawa; H Kawabe; H Seto
Journal:  AJNR Am J Neuroradiol       Date:  2010-09-02       Impact factor: 3.825

3.  Blood oxygen level dependent angiography (BOLDangio) and its potential applications in cancer research.

Authors:  Kejia Cai; Adam Shore; Anup Singh; Mohammad Haris; Teruyuki Hiraki; Prianka Waghray; Damodar Reddy; Joel H Greenberg; Ravinder Reddy
Journal:  NMR Biomed       Date:  2012-02-02       Impact factor: 4.044

Review 4.  Principles, techniques, and applications of T2*-based MR imaging and its special applications.

Authors:  Govind B Chavhan; Paul S Babyn; Bejoy Thomas; Manohar M Shroff; E Mark Haacke
Journal:  Radiographics       Date:  2009 Sep-Oct       Impact factor: 5.333

Review 5.  Clinical applications of susceptibility weighted MR imaging of the brain - a pictorial review.

Authors:  Bejoy Thomas; Sivaraman Somasundaram; Krishnamoorthy Thamburaj; Chandrasekharan Kesavadas; Arun Kumar Gupta; Narendra K Bodhey; Tirur Raman Kapilamoorthy
Journal:  Neuroradiology       Date:  2007-10-11       Impact factor: 2.804

6.  A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans.

Authors:  T J Huppert; R D Hoge; S G Diamond; M A Franceschini; D A Boas
Journal:  Neuroimage       Date:  2005-11-21       Impact factor: 6.556

7.  Assessment of myocardial oxygenation with MRI.

Authors:  Jie Zheng
Journal:  Quant Imaging Med Surg       Date:  2013-04

8.  Enhanced susceptibility-weighted angiography (ESWAN) of cerebral arteries and veins at 1.5 Tesla.

Authors:  L Chen; J Zhang; Q-X Wang; L Peng; X Luo; W-Z Zhu; A K Roshan; J-P Qi; H Wang
Journal:  Br J Radiol       Date:  2014-05-02       Impact factor: 3.039

9.  Oxygenation-sensitive CMR for assessing vasodilator-induced changes of myocardial oxygenation.

Authors:  Matthias Vöhringer; Jacqueline A Flewitt; Jordin D Green; Rohan Dharmakumar; Jiun Wang; John V Tyberg; Matthias G Friedrich
Journal:  J Cardiovasc Magn Reson       Date:  2010-03-31       Impact factor: 5.364

10.  In vivo MRI assessment of placental and foetal oxygenation changes in a rat model of growth restriction using blood oxygen level-dependent (BOLD) magnetic resonance imaging.

Authors:  S Aimot-Macron; L J Salomon; B Deloison; R Thiam; C A Cuenod; O Clement; N Siauve
Journal:  Eur Radiol       Date:  2013-02-26       Impact factor: 5.315

View more