Limits to the accuracy of vessel diameter measurement in MR angiography.

R M Hoogeveen1, C J Bakker, M A Viergever.   

Abstract

This work addresses the fundamental limits imposed by the MRI process on the accuracy with which vessel diameters and cross-sectional areas can be derived from time-of-flight (TOF) and phase-contrast (PC) MR source images. By means of simulations and in vitro experiments, it is demonstrated that, even in the absence of flow-related artifacts, severe inaccuracies in the determination of diameters or cross-sectional areas may occur solely because of the physical process of the MR image acquisition. Resolution and intraluminal saturation have strong effects on the vessel appearance and thus on the diameter estimation error. It is shown that low resolution leads to diameter overestimation or even underestimation and that intraluminal saturation causes severe underestimation, even for relatively low flip angles. Velocity and velocity encoding do not have a major influence on lumen appearance in PC images. Accurate diameter estimations can be attained only if lumen diameters constitute at least three pixels for both TOF and PC acquisitions, provided that intraluminal saturation is suppressed or avoided. Additionally, since the constitution of TOF and PC images is dissimilar, lumina should be analyzed differently to obtain accurate diameters and cross-sectional areas.

Mesh:

Year:  1998        PMID: 9848733     DOI: 10.1002/jmri.1880080608

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  27 in total

1.  Accuracy of microvascular measurements obtained from micro-CT images.

Authors:  Timothy L Kline; Mair Zamir; Erik L Ritman
Journal:  Ann Biomed Eng       Date:  2010-05-11       Impact factor: 3.934

2.  Single breathhold noncontrast thoracic MRA using highly accelerated parallel imaging with a 32-element coil array.

Authors:  Jian Xu; Kelly Anne McGorty; Ruth P Lim; Mary Bruno; James S Babb; Monvadi B Srichai; Daniel Kim; Daniel K Sodickson
Journal:  J Magn Reson Imaging       Date:  2011-12-06       Impact factor: 4.813

3.  Scan-Rescan reproducibility of carotid bifurcation geometry from routine contrast-enhanced MR angiography.

Authors:  Payam B Bijari; Luca Antiga; Bruce A Wasserman; David A Steinman
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

4.  Prospective evaluation of carotid artery stenosis: elliptic centric contrast-enhanced MR angiography and spiral CT angiography compared with digital subtraction angiography.

Authors:  Juan Alvarez-Linera; Julián Benito-León; José Escribano; Jorge Campollo; Ricardo Gesto
Journal:  AJNR Am J Neuroradiol       Date:  2003-05       Impact factor: 3.825

5.  Effects of zero-filled interpolation on cervical magnetic resonance angiographic measurement.

Authors:  Kirsten P Forbes; James G Pipe; John P Karis; Joseph E Heiserman
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

Review 6.  MRA of abdominal vessels: technical advances.

Authors:  Henrik J Michaely; Olaf Dietrich; Kambiz Nael; Sabine Weckbach; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-05-24       Impact factor: 5.315

7.  Vasodilatory capacity of the cerebral vasculature in patients with carotid artery stenosis.

Authors:  R P H Bokkers; F J Wessels; H B van der Worp; J J M Zwanenburg; W P Th M Mali; J Hendrikse
Journal:  AJNR Am J Neuroradiol       Date:  2011-03-10       Impact factor: 3.825

8.  Neurovascular changes measured by time-of-flight MR angiography in cholesterol-fed rabbits with cortical amyloid beta-peptide accumulation.

Authors:  Susan K Lemieux; Carrie A Smith-Bell; Jered R Wells; Nnadozie M Ezerioha; Jeffrey S Carpenter; D Larry Sparks; Bernard G Schreurs
Journal:  J Magn Reson Imaging       Date:  2010-08       Impact factor: 4.813

9.  Assisting vascular access surgery planning for hemodialysis by using MR, image segmentation techniques, and computer simulations.

Authors:  M A G Merkx; A S Bode; W Huberts; J Oliván Bescós; J H M Tordoir; M Breeuwer; F N van de Vosse; E M H Bosboom
Journal:  Med Biol Eng Comput       Date:  2013-03-23       Impact factor: 2.602

10.  Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study.

Authors:  Mandy M A Conijn; Jeroen Hendrikse; Jaco J M Zwanenburg; Taro Takahara; Mirjam I Geerlings; Willem P Th M Mali; Peter R Luijten
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.