Literature DB >> 12637274

Effects of zero-filled interpolation on cervical magnetic resonance angiographic measurement.

Kirsten P Forbes1, James G Pipe, John P Karis, Joseph E Heiserman.   

Abstract

BACKGROUND AND
PURPOSE: The aim of this study was to assess the effect of zero-filled interpolation (ZIP) on measurements of the cervical arteries because its benefits on the accuracy and precision of measurements in medium-sized arteries remains unknown.
METHODS: Three observers measured 36 computer-simulated vessels (2-6.8 mm) and 130 normal cervical vessels (assessed with two-dimensional time-of-flight MR angiography) from 512-, 256-, and 256-ZIP matrix source images. The accuracy and precision of measurement was assessed for each matrix by using the Student t test and F test of variance, respectively. The effect of vessel size and matrix placement on measurement error was determined by means of linear regression and the Student t test, respectively.
RESULTS: No significant difference was observed between simulated measurements obtained on the 512 matrix and their true value. The 256 matrix caused overestimation of vessel diameter compared with 512 matrix (mean bias, 0.3 mm for computer-simulated vessels and 0.1 mm for normal vessels). This effect was reduced with ZIP, by a mean of 0.1 mm for both groups (P <.03). Precision was not affected by the matrix size or ZIP, and vessel size and matrix placement did not alter the measurement error.
CONCLUSION: Vessel diameter is overestimated on 256-matrix MR angiographic source images. ZIP reduces this overestimation; however, the effect is small and unlikely to be clinically important.

Entities:  

Mesh:

Year:  2003        PMID: 12637274      PMCID: PMC7973607     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  11 in total

1.  Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries.

Authors:  J J Westenberg; R J van der Geest; M N Wasser; E L van der Linden; T van Walsum; H C van Assen; A de Roos; J Vanderschoot; J H Reiber
Journal:  Magn Reson Imaging       Date:  2000-01       Impact factor: 2.546

2.  Volume rendering and connectivity algorithms for MR angiography.

Authors:  H E Cline; C L Dumoulin; W E Lorensen; S P Souza; W J Adams
Journal:  Magn Reson Med       Date:  1991-04       Impact factor: 4.668

3.  Artifacts in maximum-intensity-projection display of MR angiograms.

Authors:  C M Anderson; D Saloner; J S Tsuruda; L G Shapeero; R E Lee
Journal:  AJR Am J Roentgenol       Date:  1990-03       Impact factor: 3.959

4.  Limits to the accuracy of vessel diameter measurement in MR angiography.

Authors:  R M Hoogeveen; C J Bakker; M A Viergever
Journal:  J Magn Reson Imaging       Date:  1998 Nov-Dec       Impact factor: 4.813

5.  The effect of image resolution on vessel signal in high-resolution magnetic resonance angiography.

Authors:  D L Parker; D J Parker; D D Blatter; Y P Du; K C Goodrich
Journal:  J Magn Reson Imaging       Date:  1996 Jul-Aug       Impact factor: 4.813

6.  Contrast-enhanced MR angiography of supraaortic vessels: the effect of voxel size on image quality.

Authors:  X Leclerc; L Nicol; J Y Gauvrit; V Le Thuc; D Leys; J P Pruvo
Journal:  AJNR Am J Neuroradiol       Date:  2000 Jun-Jul       Impact factor: 3.825

7.  Comparison of projection algorithms used for the construction of maximum intensity projection images.

Authors:  S Schreiner; C B Paschal; R L Galloway
Journal:  J Comput Assist Tomogr       Date:  1996 Jan-Feb       Impact factor: 1.826

8.  Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography.

Authors:  Y P Du; D L Parker; W L Davis; G Cao
Journal:  J Magn Reson Imaging       Date:  1994 Sep-Oct       Impact factor: 4.813

9.  Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis.

Authors:  H J M Barnett; D W Taylor; R B Haynes; D L Sackett; S J Peerless; G G Ferguson; A J Fox; R N Rankin; V C Hachinski; D O Wiebers; M Eliasziw
Journal:  N Engl J Med       Date:  1991-08-15       Impact factor: 91.245

10.  Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators.

Authors:  H J Barnett; D W Taylor; M Eliasziw; A J Fox; G G Ferguson; R B Haynes; R N Rankin; G P Clagett; V C Hachinski; D L Sackett; K E Thorpe; H E Meldrum; J D Spence
Journal:  N Engl J Med       Date:  1998-11-12       Impact factor: 91.245

View more
  2 in total

1.  On the influence of zero-padding on the nonlinear operations in Quantitative Susceptibility Mapping.

Authors:  Sarah Eskreis-Winkler; Dong Zhou; Tian Liu; Ajay Gupta; Susan A Gauthier; Yi Wang; Pascal Spincemaille
Journal:  Magn Reson Imaging       Date:  2016-08-29       Impact factor: 2.546

2.  High-quality imaging of endolymphatic hydrops acquired in 7 minutes using sensitive hT2W-3D-FLAIR reconstructed with magnitude and zero-filled interpolation.

Authors:  Jing Zou; Luguang Chen; Hongbin Li; Guoping Zhang; Ilmari Pyykkö; Jianping Lu
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-06-18       Impact factor: 3.236

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.