Literature DB >> 9845442

Continuous, flow-through immunomagnetic cell sorting in a quadrupole field.

L Sun1, M Zborowski, L R Moore, J J Chalmers.   

Abstract

A flow-through quadrupole magnetic cell separator has been designed, built, and evaluated by using a cell model system of human peripheral T lymphocytes (CD4+, CD8+, and CD45+ cells). The immunomagnetic labeling was accomplished by using a sandwich of mouse anti-human monoclonal antibody conjugated to fluorescein isothiocyanate and rat anti-mouse polyclonal antibody conjugated to a colloidal magnetic nanoparticle. The feed and sorted fractions were analyzed by FACScan flow cytometry. The magnetically labeled cells were separated from nonlabeled ones in a flow-through cylindrical column within a quadrupole field, which exerted a radial, outward force on the magnetic cells. The flow rate of the cell samples was 0.1-0.75 ml/min, and the flow rate of sheath fluid was 1.5-33.3 times that of the sample flow rate. The maximum shear stress exerted on the cell was less than 1 dyne/cm2, which was well below the level that would threaten cell integrity and membrane disruption. The maximum magnetic field was 0.765 T at the channel wall, and the gradient was 0.174 T/mm. The highest purity of selected cells was 99.6% (CD8 cells, initial purity of 26%), and the highest recovery of selected cells was 79% (CD4 cells, initial purity of 20%). The maximum throughput of the quadrupole magnetic cell separator was 7,040 cells/s (CD45 cells, initial purity of 5%). Theoretical calculations showed that the throughput can be increased to 10(6) cells/s by a scale-up of the current prototype.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9845442     DOI: 10.1002/(sici)1097-0320(19981201)33:4<469::aid-cyto11>3.0.co;2-6

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  11 in total

1.  Mechanotransduction Effects on Endothelial Cell Proliferation via CD31 and VEGFR2: Implications for Immunomagnetic Separation.

Authors:  Kalpesh D Mahajan; Gauri M Nabar; Wei Xue; Mirela Anghelina; Nicanor I Moldovan; Jeffrey J Chalmers; Jessica O Winter
Journal:  Biotechnol J       Date:  2017-08-14       Impact factor: 4.677

2.  Computational Fluid Dynamics Simulation of a Quadrupole Magnetic Sorter Flow Channel: Effect of Splitter Position on Nonspecific Crossover.

Authors:  V S K Sajja; David J Kennedy; Paul W Todd; Thomas R Hanley
Journal:  Can J Chem Eng       Date:  2011-10       Impact factor: 2.007

3.  Quantification of both the presence, and oxidation state, of Mn in Bacillus atrophaeus spores and its imparting of magnetic susceptibility to the spores.

Authors:  Jianxin Sun; Maciej Zborowski; Jeffrey J Chalmers
Journal:  Biotechnol Bioeng       Date:  2011-01-04       Impact factor: 4.530

4.  Fast sorting of CD4+ T cells from whole blood using glass microbubbles.

Authors:  Chia-Hsien Hsu; Chihchen Chen; Daniel Irimia; Mehmet Toner
Journal:  Technology (Singap World Sci)       Date:  2015-03

5.  SPIONs self-assembly and magnetic sedimentation in quadrupole magnets: Gaining insight into the separation mechanisms.

Authors:  Xian Wu; Jenifer Gómez-Pastora; Maciej Zborowski; Jeffrey Chalmers
Journal:  Sep Purif Technol       Date:  2021-09-22       Impact factor: 7.312

6.  Characterization of nonspecific crossover in split-flow thin channel fractionation.

Authors:  P Stephen Williams; Mauricio Hoyos; Pascal Kurowski; Dorra Salhi; Lee R Moore; Maciej Zborowski
Journal:  Anal Chem       Date:  2008-08-13       Impact factor: 6.986

7.  Quadrupole magnetic sorting of porcine islets of Langerhans.

Authors:  Rustin M Shenkman; Jeffrey J Chalmers; Bernhard J Hering; Nicole Kirchhof; Klearchos K Papas
Journal:  Tissue Eng Part C Methods       Date:  2009-06       Impact factor: 3.056

8.  Optimization of an enrichment process for circulating tumor cells from the blood of head and neck cancer patients through depletion of normal cells.

Authors:  Liying Yang; James C Lang; Priya Balasubramanian; Kris R Jatana; David Schuller; Amit Agrawal; Maciej Zborowski; Jeffrey J Chalmers
Journal:  Biotechnol Bioeng       Date:  2009-02-01       Impact factor: 4.530

9.  Continuous, intrinsic magnetic depletion of erythrocytes from whole blood with a quadrupole magnet and annular flow channel; pilot scale study.

Authors:  Lee R Moore; Daichi Mizutani; Tomoya Tanaka; Amy Buck; Mark Yazer; Maciej Zborowski; Jeffrey J Chalmers
Journal:  Biotechnol Bioeng       Date:  2018-03-13       Impact factor: 4.530

10.  Design, fabrication and demonstration of a magnetophoresis chamber with 25 output fractions.

Authors:  Chris Carr; Michelle Espy; Pulak Nath; Sara L Martin; Michael D Ward; John Martin
Journal:  J Magn Magn Mater       Date:  2009-05       Impact factor: 2.993

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.