Literature DB >> 21984840

Computational Fluid Dynamics Simulation of a Quadrupole Magnetic Sorter Flow Channel: Effect of Splitter Position on Nonspecific Crossover.

V S K Sajja1, David J Kennedy, Paul W Todd, Thomas R Hanley.   

Abstract

In the Quadrupole Magnetic Sorter (QMS) magnetic particles enter a vertical flow annulus and are separated from non-magnetic particles by radial deflection into an outer annulus where the purified magnetic particles are collected via a flow splitter. The purity of magnetically isolated particles in QMS is affected by the migration of nonmagnetic particles across transport lamina in the annular flow channel. Computational Fluid Dynamics (CFD) simulations were used to predict the flow patterns, pressure drop and nonspecific crossover in QMS flow channel for the isolation of pancreatic islets of Langerhans. Simulation results were compared with the experimental results to validate the CFD model. Results of the simulations were used to show that one design gives up to 10% less nonspecific crossover than another and this model can be used to optimise the flow channel design to achieve maximum purity of magnetic particles.

Entities:  

Year:  2011        PMID: 21984840      PMCID: PMC3185364          DOI: 10.1002/cjce.20541

Source DB:  PubMed          Journal:  Can J Chem Eng        ISSN: 0008-4034            Impact factor:   2.007


  18 in total

1.  Splitter imperfections in annular split-flow thin separation channels: experimental study of nonspecific crossover.

Authors:  P Stephen Williams; Keith Decker; Masayuki Nakamura; Jeffrey J Chalmers; Lee R Moore; Maciej Zborowski
Journal:  Anal Chem       Date:  2003-12-01       Impact factor: 6.986

2.  Splitter imperfections in annular split-flow thin separation channels: effect on nonspecific crossover.

Authors:  P Stephen Williams; Lee R Moore; Jeffrey J Chalmers; Maciej Zborowski
Journal:  Anal Chem       Date:  2003-03-15       Impact factor: 6.986

3.  Effect of flow development region and fringing magnetic force field on annular split-flow thin fractionation.

Authors:  Yonghao Zhang; David R Emerson
Journal:  J Chromatogr A       Date:  2004-07-09       Impact factor: 4.759

4.  Islet purification by a novel immunomicrosphere cell depletion technique.

Authors:  P Soon-Shiong; T Fujioka; P Terasaki; R Heintz; R P Lanza
Journal:  Transplant Proc       Date:  1990-04       Impact factor: 1.066

5.  New principle for large-scale preparation of purified human pancreas islets.

Authors:  S Winoto-Morbach; K Ulrichs; G Leyhausen; W Müller-Ruchholtz
Journal:  Diabetes       Date:  1989-01       Impact factor: 9.461

6.  Blood progenitor cell separation from clinical leukapheresis product by magnetic nanoparticle binding and magnetophoresis.

Authors:  Ying Jing; Lee R Moore; P Stephen Williams; Jeffrey J Chalmers; Sherif S Farag; Brian Bolwell; Maciej Zborowski
Journal:  Biotechnol Bioeng       Date:  2007-04-15       Impact factor: 4.530

7.  A novel high throughput immunomagnetic cell sorting system for potential clinical scale depletion of T cells for allogeneic stem cell transplantation.

Authors:  Xiaodong Tong; Ying Xiong; Maciej Zborowski; Sherif S Farag; Jeffrey J Chalmers
Journal:  Exp Hematol       Date:  2007-08-13       Impact factor: 3.084

8.  Continuous, flow-through immunomagnetic cell sorting in a quadrupole field.

Authors:  L Sun; M Zborowski; L R Moore; J J Chalmers
Journal:  Cytometry       Date:  1998-12-01

9.  Gelatin density gradient for isolation of islets of Langerhans.

Authors:  T Samejima; K Yamaguchi; H Iwata; N Morikawa; Y Ikada
Journal:  Cell Transplant       Date:  1998 Jan-Feb       Impact factor: 4.139

10.  Factors that affect human islet isolation.

Authors:  Y Sakuma; C Ricordi; A Miki; T Yamamoto; A Pileggi; A Khan; R Alejandro; L Inverardi; H Ichii
Journal:  Transplant Proc       Date:  2008-03       Impact factor: 1.066

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.