Literature DB >> 9835670

Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults.

L A Jensen1, J E Onyskiw, N G Prasad.   

Abstract

OBJECTIVE: The purposes of the study were to: (1) describe the aggregate strength of the relationship of arterial oxygen saturation as measured by pulse oximetry with the standard of arterial blood gas analysis as measured by co-oximetry, (2) examine how various factors affect this relationship, and (3) describe an aggregate estimate of the bias and precision between oxygen saturation as measured by pulse oximetry and the standard in vitro measures.
DESIGN: A meta-analysis was conducted. SAMPLE: Seventy-four studies from 1976 to 1994 met the inclusion criteria of: (1) adult study population, (2) quantitative analysis of empirical data, and (3) bivariate correlations or bias and precision estimates between pulse oximeter and co-oximeter values.
RESULTS: There were a total of 169 oximeter trials on 41 oximeter models from 25 different manufacturers. Studies were conducted in various settings with a variety of subjects, with most being healthy adult volunteers. The weighted mean r, based on 39 studies (62 oximeter trials) for which the r statistic and number of data points were available, was 0.895 (var [r] = 0.014). Based on 23 studies (82 oximeter trials) for which bias and precision estimates and number of data points were available, the mean absolute bias and precision were 1.999 and 0.233, respectively. Several factors were found to affect the accuracy of pulse oximetry.
CONCLUSION: Pulse oximeters were found to be accurate within 2% (+/- 1 SD) or 5% (+/- 2 SD) of in vitro oximetry in the range of 70% to 100% Sao2. In comparing ear and finger probes, readings from finger probes were more accurate. Pulse oximeters may fail to record accurately the true Sao2 during severe or rapid desaturation, hypotension, hypothermia, dyshemoglobinemia, and low perfusion states.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9835670     DOI: 10.1016/s0147-9563(98)90086-3

Source DB:  PubMed          Journal:  Heart Lung        ISSN: 0147-9563            Impact factor:   2.210


  36 in total

1.  Comparison of a prototype esophageal oximetry probe with two conventional digital pulse oximetry monitors in aortocoronary bypass patients.

Authors:  R C Prielipp; P E Scuderi; M H Hines; J L Atlee; J F Butterworth
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

2.  Dyspnea reproducibility in a rural Bangladesh population.

Authors:  Gene Raymond Pesola; Faruque Parvez; Sultana Jasmin; Abul Kalam Mohammad Rabiul Hasan; Habibul Ahsan
Journal:  Clin Respir J       Date:  2009-10       Impact factor: 2.570

3.  The role of pulse oximetry in chiropractic practice: a rationale for its use.

Authors:  Michael W Hall; Anne M Jensen
Journal:  J Chiropr Med       Date:  2012-06

4.  A framework for the meta-analysis of Bland-Altman studies based on a limits of agreement approach.

Authors:  Elizabeth Tipton; Jonathan Shuster
Journal:  Stat Med       Date:  2017-06-29       Impact factor: 2.373

5.  Comparative Evaluation of Accuracy of Pulse Oximeters and Factors Affecting Their Performance in a Tertiary Intensive Care Unit.

Authors:  Anupam Kumar Singh; Malvinder Singh Sahi; Bablesh Mahawar; Sajjan Rajpurohit
Journal:  J Clin Diagn Res       Date:  2017-06-01

6.  Arterial blood gas and pulse oximetry in initial management of patients with community-acquired pneumonia.

Authors:  K P Levin; B H Hanusa; A Rotondi; D E Singer; C M Coley; T J Marrie; W N Kapoor; M J Fine
Journal:  J Gen Intern Med       Date:  2001-09       Impact factor: 5.128

7.  Glycemic control influences lung membrane diffusion and oxygen saturation in exercise-trained subjects with type 1 diabetes: alveolar-capillary membrane conductance in type 1 diabetes.

Authors:  Courtney M Wheatley; James C Baldi; Nicholas A Cassuto; William T Foxx-Lupo; Eric M Snyder
Journal:  Eur J Appl Physiol       Date:  2010-10-10       Impact factor: 3.078

8.  Exercise peripheral oxygen saturation (SpO2) accurately reflects arterial oxygen saturation (SaO2) and predicts mortality in systemic sclerosis.

Authors:  J J Swigris; X Zhou; F S Wamboldt; R du Bois; R Keith; A Fischer; G P Cosgrove; S K Frankel; D Curran-Everett; K K Brown
Journal:  Thorax       Date:  2009-04-08       Impact factor: 9.139

9.  Peripheral venous blood gases and pulse-oximetry in acute cardiogenic pulmonary oedema.

Authors:  J Masip; D De Mendoza; K Planas; J Paez; B Sanchez; B Cancio
Journal:  Eur Heart J Acute Cardiovasc Care       Date:  2012-12

10.  Validation of the WristOx 3100 oximeter for the diagnosis of sleep apnea/hypopnea syndrome.

Authors:  Carlos Alberto Nigro; Silvia Aimaretti; Sergio Gonzalez; Edgardo Rhodius
Journal:  Sleep Breath       Date:  2008-10-02       Impact factor: 2.816

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.