PURPOSE: To evaluate the association between baseline ocular variables and the widening of the anterior chamber angle by laser peripheral iridotomy (LPI) in primary angle closure suspects (PACS) using a new Fourier-domain swept-source anterior segment optical coherence tomography (FD-ASOCT).
METHOD: Sixty-six PACS eyes of 41 individuals were enrolled in this prospective interventional case series. An FD-ASOCT (Casia SS-1000 OCT; Tomey, Nagoya, Japan) was used to measure biometric baseline variables and at 1 month after the LPI. Paired t test was used to compare the difference between pre-and post-LPI measurements. Multivariate regression analysis was used to test for an association between baseline iris thickness and volume, anterior chamber depth and volume, and lens vault with a widening of the angle after an LPI. Changes in trabecular iris space area and angle opening distance after the LPI were main outcome measures.
RESULTS: The mean age of participants was 58.6 ± 8.7 years, 68.2% of whom were female. The angle opening distance, recess area, and trabecular iris surface area at 500 μm increased by 48 to 73% (all P < 0.001). Lens vault and iris volume did not change. A low anterior chamber volume and low iris volume were associated with angle greater deepening by LPI.
CONCLUSION: Eyes with a shallow anterior chamber and thinner irises are more likely to experience angle opening from an LPI.

Entities:  

Keywords:  Anterior chamber volume, iris volume, CASIA OCT; Laser peripheral iridotomy, swept-source anterior segment OCT; Primary angle closure suspect

Mesh:

Year:  2018        PMID: 30073624      PMCID: PMC7809532          DOI: 10.1007/s00417-018-4092-8

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  38 in total

1.  Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement.

Authors:  Shu Liu; Marco Yu; Cong Ye; Dennis S C Lam; Christopher Kai-Shun Leung
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-11-04       Impact factor: 4.799

2.  Morphological changes of the anterior segment after laser peripheral iridotomy in primary angle closure.

Authors:  K Lei; N Wang; L Wang; B Wang
Journal:  Eye (Lond)       Date:  2007-12-07       Impact factor: 3.775

3.  Biometry and primary angle-closure glaucoma among Chinese, white, and black populations.

Authors:  N G Congdon; Q Youlin; H Quigley; P T Hung; T H Wang; T C Ho; J M Tielsch
Journal:  Ophthalmology       Date:  1997-09       Impact factor: 12.079

4.  Anterior chamber volume. Its measurement and clinical application.

Authors:  R L Coakes; D Lloyd-Jones; R A Hitchings
Journal:  Trans Ophthalmol Soc U K       Date:  1979-04

5.  Laser iridotomy in the treatment of angle-closure glaucoma.

Authors:  I P Pollack
Journal:  Ann Ophthalmol       Date:  1981-05

6.  Anterior chamber dimensions in patients with narrow angles and angle-closure glaucoma.

Authors:  D A Lee; R F Brubaker; D M Ilstrup
Journal:  Arch Ophthalmol       Date:  1984-01

7.  Five year risk of progression of primary angle closure suspects to primary angle closure: a population based study.

Authors:  R Thomas; R George; R Parikh; J Muliyil; A Jacob
Journal:  Br J Ophthalmol       Date:  2003-04       Impact factor: 4.638

8.  Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma.

Authors:  G Marchini; A Pagliarusco; A Toscano; R Tosi; C Brunelli; L Bonomi
Journal:  Ophthalmology       Date:  1998-11       Impact factor: 12.079

Review 9.  Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis.

Authors:  Yih-Chung Tham; Xiang Li; Tien Y Wong; Harry A Quigley; Tin Aung; Ching-Yu Cheng
Journal:  Ophthalmology       Date:  2014-06-26       Impact factor: 12.079

10.  Ultrasound biomicroscopic features associated with angle closure in fellow eyes of acute primary angle closure after laser iridotomy.

Authors:  Bao-qun Yao; Ling-ling Wu; Chun Zhang; Xin Wang
Journal:  Ophthalmology       Date:  2009-01-20       Impact factor: 12.079

View more
  2 in total

1.  Segmentation Errors in the Measurement of Volumetric Parameters by Swept-Source Anterior Segment Optical Coherence Tomography.

Authors:  Hailiu Chen; Jie Meng; Peng Lu; Dan Ye; Yunxuan Li; Lu Cheng; Yangyunhui Li; Xiaoling Liang; Wenyong Huang; Jingjing Huang
Journal:  Front Med (Lausanne)       Date:  2021-12-17

2.  Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2.

Authors:  Xiaoxiao Chen; Xiaolei Wang; Xinghuai Sun; Yuhong Chen; Yizhen Tang
Journal:  BMC Ophthalmol       Date:  2022-03-28       Impact factor: 2.209

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.