Literature DB >> 9814514

Calculation of depth dose and dose per monitor unit for irregularly shaped electron fields.

F M Khan1, P D Higgins, B J Gerbi, F C Deibel, A Sethi, D N Mihailidis.   

Abstract

A new dosimetric quantity, the lateral build-up ratio (LBR), has been introduced to calculate depth dose distribution for any shaped field. Factors to account for change in incident fluence with collimation are applied separately. The LBR data for a small circular field are used to extract radial spread of the pencil beam, sigma(r), as a function of depth and energy. By using the relationship between LBR, sigma(r), energy and depth, a formalism is developed to calculate dose per monitor unit for any shaped field. Criteria for lateral scatter equilibrium are also developed which are useful in clinical dosimetry.

Mesh:

Year:  1998        PMID: 9814514     DOI: 10.1088/0031-9155/43/10/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

Review 2.  Some computer graphical user interfaces in radiation therapy.

Authors:  James C L Chow
Journal:  World J Radiol       Date:  2016-03-28

3.  Characterization of irregular electron beam for boost dose after whole breast irradiation.

Authors:  Ayat M Saadeldin; Azhar M Elwan
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-22

4.  The effects of cutouts on output, mean energy and percentage depth dose of 12 and 14 MeV electrons.

Authors:  Navid Khaledy; Azim Arbabi; Dariush Sardari
Journal:  J Med Phys       Date:  2011-10

5.  Monte Carlo calculations of output factors for clinically shaped electron fields.

Authors:  Julius V Turian; Brett D Smith; Damian A Bernard; Katherine L Griem; James C Chu
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

6.  The Study of Field Equivalence Determined by the Modeled Percentage Depth Dose in Electron Beam Radiation Therapy.

Authors:  You-Guo Ma; Yan-Shan Zhang; Yan-Cheng Ye; Jia-Ming Wu
Journal:  Biomed Res Int       Date:  2021-10-08       Impact factor: 3.411

7.  Determination of square equivalent field for rectangular field in electron therapy.

Authors:  Mohammad J Tahmasebi Birgani; Mohammad A Behrouz; Saeedeh Aliakbari; Seyed M Hosseini; Davood Khezerloo
Journal:  J Med Phys       Date:  2013-04

8.  Experimental verification of the application of lateral buildup ratio on the 4-MeV electron beam.

Authors:  James C L Chow; Scott Newman
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

9.  A graphical user interface for an electron monitor unit calculator using a sector-integration algorithm and exponential curve-fitting method.

Authors:  James C L Chow; Grigor N Grigorov; Christopher MacGregor
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

10.  Convolution-based modified Clarkson integration (CMCI) for electron cutout factor calculation.

Authors:  Jina Chang; Mu-Han Lin; Weiguo Lu; Mingli Chen; Steve Jiang
Journal:  J Appl Clin Med Phys       Date:  2018-02-03       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.