Literature DB >> 9813806

Photoelastic stress patterns produced by implant-retained overdentures.

R Kenney1, M W Richards.   

Abstract

STATEMENT OF PROBLEM: When 2 implants are used to support a removable overdenture, optimal stress distribution to minimize forces to the implants is desired.
PURPOSE: This study used photoelastic analysis to compare the stress patterns generated around implants with 2 retention mechanisms.
MATERIAL AND METHODS: Two root form implants were anchored in a photoelastic mandible and a removable overdenture was fabricated. The denture was lined with a resilient layer of impression material to simulate oral mucosa. Attachment of the denture to the implants was varied by using ball/O-ring and bar-clip attachments. Vertical and oblique occlusal forces from 10 to 200 lb were applied unilaterally to the right and left first molars. Resultant stress distributions in the photoelastic mandible were photographed and evaluated.
RESULTS: With vertical forces, the ball/O-ring attachment transferred minimal stress to both implants. Vertical forces applied to the bar-clip overdenture created immediate stress patterns of greater magnitude and concentration on both implants. A posterior oblique load resulted in similar stress patterns to both systems with slightly greater stress to the bar-clip overdenture.
CONCLUSIONS: Within the limits of this study, ball/O-ring attachments transferred less stress to implants than the bar-clip attachments when the photoelastic model was subjected to a posterior vertical load.

Mesh:

Substances:

Year:  1998        PMID: 9813806     DOI: 10.1016/s0022-3913(98)70032-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  13 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  A finite element analysis of stress distribution in the bone, around the implant supporting a mandibular overdenture with ball/o ring and magnetic attachment.

Authors:  Jins John; V Rangarajan; Ravindra C Savadi; K S Satheesh Kumar; Preeti Satheesh Kumar
Journal:  J Indian Prosthodont Soc       Date:  2012-03-09

3.  All in one: a case report.

Authors:  M Praveen; A Chandrasekar; A Gautam; V Jothi Rathinam; Aarti Saxena
Journal:  J Indian Prosthodont Soc       Date:  2013-01-01

4.  Photoelastic stress analysis surrounding implant-supported prosthesis and alveolar ridge on mandibular overdentures.

Authors:  Dorival Pedroso da Silva; Claudia Cazal; Fernanda Campos Sousa de Almeida; Reinaldo Brito E Dias; Rafael Yagüe Ballester
Journal:  Int J Dent       Date:  2010-05-10

Review 5.  Biomechanical factors related to occlusal load transfer in removable complete dentures.

Authors:  Jarosław Żmudzki; Grzegorz Chladek; Jacek Kasperski
Journal:  Biomech Model Mechanobiol       Date:  2014-12-20

6.  Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever.

Authors:  Ji-Man Park; Hyun-Joo Kim; Eun-Jin Park; Myung-Rae Kim; Sun-Jong Kim
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

7.  Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants.

Authors:  Behnaz Ebadian; Ramin Mosharraf; Niloufar Khodaeian
Journal:  Eur J Dent       Date:  2016 Jul-Sep

8.  Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study.

Authors:  Soumyadev Satpathy; C L Satish Babu; Shilpa Shetty; Bharat Raj
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

9.  Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis.

Authors:  Behnaz Ebadian; Mahmoud Farzin; Saeid Talebi; Niloufar Khodaeian
Journal:  Dent Res J (Isfahan)       Date:  2012-11

10.  Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.

Authors:  Moustafa Abdou Elsyad; Fathi Abo Setta; Ahmed Samir Khirallah
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

View more