Literature DB >> 7792401

Accuracy of field alignment in radiotherapy of head and neck cancer utilizing individualized face mask immobilization: a retrospective analysis of clinical practice.

C F Hess1, R D Kortmann, R Jany, A Hamberger, M Bamberg.   

Abstract

Deviations between simulation and first check films were quantitatively assessed for 95 unselected head and neck cancer patients. All measured deviations--calculated on the basis of a total of 190 simulation and 380 verification films--were normally distributed, with mean values of 0-3 mm and standard deviations of 3-5 mm. Of the absolute deviations, 50% and 95% were within 3 mm and 9 mm, respectively. These results should be considered in clinical practice when prescribing safety margins and adequate cut off doses for sparing critical organs in head and neck cancer.

Entities:  

Mesh:

Year:  1995        PMID: 7792401     DOI: 10.1016/0167-8140(94)01497-q

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  8 in total

1.  [HIT'91: Precision and acute maximal side effects of radiotherapy of craniospinal axis. Concerning the contribution by R.D. Kortmann et al., Strahlenther Onkol 1999;175:162-9 (No.4)].

Authors:  E Weiss; C F Hess
Journal:  Strahlenther Onkol       Date:  1999-05       Impact factor: 3.621

2.  HIT '91 (prospective, co-operative study for the treatment of malignant brain tumors in childhood): accuracy and acute toxicity of the irradiation of the craniospinal axis. Results of the quality assurance program.

Authors:  R D Kortmann; B Timmermann; J Kühl; N Willich; M Flentje; C Meisner; M Bamberg
Journal:  Strahlenther Onkol       Date:  1999-04       Impact factor: 3.621

3.  Reproducibility of irregular radiation fields for malignant lymphoma.

Authors:  U Mock; K Dieckmann; A M Molitor; U Haverkamp; R Pötter
Journal:  Strahlenther Onkol       Date:  1998-10       Impact factor: 3.621

Review 4.  Patient positioning and immobilization procedures for hybrid MR-Linac systems.

Authors:  Francesco Cuccia; Filippo Alongi; Claus Belka; Luca Boldrini; Juliane Hörner-Rieber; Helen McNair; Michele Rigo; Maartje Schoenmakers; Maximilian Niyazi; Judith Slagter; Claudio Votta; Stefanie Corradini
Journal:  Radiat Oncol       Date:  2021-09-20       Impact factor: 3.481

5.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

6.  Impact of geometric uncertainties on dose distribution during intensity modulated radiotherapy of head-and-neck cancer: the need for a planning target volume and a planning organ-at-risk volume.

Authors:  O Ballivy; W Parker; T Vuong; G Shenouda; H Patrocinio
Journal:  Curr Oncol       Date:  2006-06       Impact factor: 3.677

7.  Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device.

Authors:  Tejpal Gupta; Supriya Chopra; Avinash Kadam; Jai Prakash Agarwal; P Reena Devi; Sarbani Ghosh-Laskar; Ketayun Ardeshir Dinshaw
Journal:  Radiat Oncol       Date:  2007-12-14       Impact factor: 3.481

8.  Impact of different CBCT imaging monitor units, reconstruction slice thicknesses, and planning CT slice thicknesses on the positioning accuracy of a MV-CBCT system in head-and-neck patients.

Authors:  Ming X Jia; Xu Zhang; Na Li; Cheng B Han
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.