Megavoltage imaging with low Z targets: implementation and characterization of an investigational system.

O Z Ostapiak1, P F O'Brien, B A Faddegon.   

Abstract

The poor quality of stereotactic radiotherapy portal images is a limiting factor in precise image registration. To alleviate this problem, a low atomic number (Z) target was implemented on our Siemens MXE linear accelerator. This investigational system was used to assess the performance of various target materials by filming an aluminum contrast object. Beryllium, carbon and conventional target materials were studied. The bremsstrahlung spectra of these materials were simulated using Monte Carlo techniques. These spectra were used to calculate the dependence of narrow beam contrast on phantom thickness for verification of the data measured from film. A Monte Carlo simulation of the beryllium spectrum in a wide beam geometry was used to evaluate the effect of phantom-to-film distance on contrast. Although the same degree of contrast improvement with distance was not realized in practice, the improvement in image quality rivaled that achieved using a scatter reduction grid. A comparison of conventional localization images of the head and neck of an anthropomorphic phantom with images produced with a beryllium or carbon target and a mammography film and screen system supports earlier suggestions that the technique is clinically useful.

Entities:  

Mesh:

Year:  1998        PMID: 9800698     DOI: 10.1118/1.598380

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

2.  Dosimetric properties and commissioning of cone-beam CT image beam line with a carbon target.

Authors:  Y Dzierma; F G Nuesken; N P Licht; C Ruebe
Journal:  Strahlenther Onkol       Date:  2013-05-30       Impact factor: 3.621

3.  [Organizational models of inpatient emergency and acute care].

Authors:  A Kaltwasser; C Dodt
Journal:  Med Klin Intensivmed Notfmed       Date:  2014-10       Impact factor: 0.840

4.  Image quality and dose distributions of three linac-based imaging modalities.

Authors:  Yvonne Dzierma; Evemarie Ames; Frank Nuesken; Jan Palm; Norbert Licht; Christian Rübe
Journal:  Strahlenther Onkol       Date:  2014-12-20       Impact factor: 3.621

5.  Investigation of the use of external aluminium targets for portal imaging in a medical accelerator using Geant4 Monte Carlo simulation.

Authors:  Hyungdong Kim; Byungyong Kim; Jonggeun Baek; Youngkee Oh; Sangmo Yun; Hyunsoo Jang
Journal:  Br J Radiol       Date:  2018-02-06       Impact factor: 3.039

6.  Influence of daily imaging on plan quality and normal tissue toxicity for prostate cancer radiotherapy.

Authors:  Katharina Bell; Marina Heitfeld; Norbert Licht; Christian Rübe; Yvonne Dzierma
Journal:  Radiat Oncol       Date:  2017-01-10       Impact factor: 3.481

7.  Influence of acquisition parameters on MV-CBCT image quality.

Authors:  Olivier Gayou
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

8.  Investigation of planar image quality for a novel 2.5 MV diamond target beam from a radiotherapy linear accelerator.

Authors:  Jennifer M Borsavage; Amanda Cherpak; James L Robar
Journal:  Phys Imaging Radiat Oncol       Date:  2020-11-05

9.  Characterization of a 2.5 MV inline portal imaging beam.

Authors:  James L Gräfe; Jennifer Owen; J Eduardo Villarreal-Barajas; Rao F H Khan
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

10.  Image guidance and positioning accuracy in clinical practice: influence of positioning errors and imaging dose on the real dose distribution for head and neck cancer treatment.

Authors:  Katharina Bell; Norbert Licht; Christian Rübe; Yvonne Dzierma
Journal:  Radiat Oncol       Date:  2018-10-01       Impact factor: 3.481

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.