Literature DB >> 9799190

1998 equivalence of sensory responses to single and mixed volatile organic compounds at equimolar concentrations.

J D Prah1.   

Abstract

Exposure to low levels of chemicals indoors is often to a mixture of volatile organic compounds (VOCs). It is of interest to determine if the symptomatic and sensory responses can be attributed to a single chemical or to a mixture of chemicals. To determine if sensory or symptomatic responses differ with exposure to single or mixed VOCs, 100 female subjects participated in a 6-hr exposure study. Subjects were exposed to one of six equimolar concentrations equivalent to 24 mg/m3 toluene, control, m-xylene, n-butyl acetate, m-xylene plus n-butyl acetate, a mixture of 21 chemicals including n-butyl acetate and m-xylene, and to the same mixture of chemicals without n-butyl acetate and m-xylene (19 chemicals). The results indicated that there was no difference in reporting of symptoms or sensory responses between the exposures. When the control group was added, some variables, primarily odor intensity and nasal irritation, attained significance.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9799190      PMCID: PMC1533475          DOI: 10.1289/ehp.98106739

Source DB:  PubMed          Journal:  Environ Health Perspect        ISSN: 0091-6765            Impact factor:   9.031


  11 in total

1.  ON THE INTENSITY OF ODOR MIXTURES.

Authors:  F N JONES; M H WOSKOW
Journal:  Ann N Y Acad Sci       Date:  1964-07-30       Impact factor: 5.691

2.  Exposure of humans to a volatile organic mixture. II. Sensory.

Authors:  H K Hudnell; D A Otto; D E House; L Mølhave
Journal:  Arch Environ Health       Date:  1992 Jan-Feb

3.  High prevalence of sick building syndrome in a new air-conditioned building in Italy.

Authors:  G Abbritti; G Muzi; M P Accattoli; T Fiordi; M Dell'Omo; C Colangeli; A R Gabrielli; T Fabbri; A D'Alessandro
Journal:  Arch Environ Health       Date:  1992 Jan-Feb

4.  Odor perception and beliefs about risk.

Authors:  P Dalton
Journal:  Chem Senses       Date:  1996-08       Impact factor: 3.160

Review 5.  The epidemiology of building-related complaints and illness.

Authors:  K Kreiss
Journal:  Occup Med       Date:  1989 Oct-Dec

6.  Sick building syndrome: a study of 4373 office workers.

Authors:  S Burge; A Hedge; S Wilson; J H Bass; A Robertson
Journal:  Ann Occup Hyg       Date:  1987

7.  Development of a database for sensory irritants and its use in establishing occupational exposure limits.

Authors:  M Schaper
Journal:  Am Ind Hyg Assoc J       Date:  1993-09

Review 8.  Odor as an aid to chemical safety: odor thresholds compared with threshold limit values and volatilities for 214 industrial chemicals in air and water dilution.

Authors:  J E Amoore; E Hautala
Journal:  J Appl Toxicol       Date:  1983-12       Impact factor: 3.446

9.  Cross-modality matching functions generated by magnitude estimation.

Authors:  J C Stevens; L E Marks
Journal:  Percept Psychophys       Date:  1980-05

10.  Perceived odor, irritation, and health symptoms following short-term exposure to acetone.

Authors:  P Dalton; C J Wysocki; M J Brody; H J Lawley
Journal:  Am J Ind Med       Date:  1997-05       Impact factor: 2.214

View more
  4 in total

1.  Sickness response symptoms among healthy volunteers after controlled exposures to diesel exhaust and psychological stress.

Authors:  Robert J Laumbach; Howard M Kipen; Kathie Kelly-McNeil; Junfeng Zhang; Lin Zhang; Paul J Lioy; Pamela Ohman-Strickland; Jing Gong; Alexander Kusnecov; Nancy Fiedler
Journal:  Environ Health Perspect       Date:  2011-02-17       Impact factor: 9.031

2.  Health effects of a mixture of indoor air volatile organics, their ozone oxidation products, and stress.

Authors:  Nancy Fiedler; Robert Laumbach; Kathie Kelly-McNeil; Paul Lioy; Zhi-Hua Fan; Junfeng Zhang; John Ottenweller; Pamela Ohman-Strickland; Howard Kipen
Journal:  Environ Health Perspect       Date:  2005-11       Impact factor: 9.031

3.  Controlled human exposure to methyl tertiary butyl ether in gasoline: symptoms, psychophysiologic and neurobehavioral responses of self-reported sensitive persons.

Authors:  N Fiedler; K Kelly-McNeil; S Mohr; P Lehrer; R E Opiekun; C Lee; T Wainman; R Hamer; C Weisel; R Edelberg; P J Lioy
Journal:  Environ Health Perspect       Date:  2000-08       Impact factor: 9.031

Review 4.  Immunopathological features of air pollution and its impact on inflammatory airway diseases (IAD).

Authors:  Philip W Rouadi; Samar A Idriss; Robert M Naclerio; David B Peden; Ignacio J Ansotegui; Giorgio Walter Canonica; Sandra Nora Gonzalez-Diaz; Nelson A Rosario Filho; Juan Carlos Ivancevich; Peter W Hellings; Margarita Murrieta-Aguttes; Fares H Zaitoun; Carla Irani; Marilyn R Karam; Jean Bousquet
Journal:  World Allergy Organ J       Date:  2020-10-05       Impact factor: 4.084

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.