High prevalence of sick building syndrome in a new air-conditioned building in Italy.

G Abbritti1, G Muzi, M P Accattoli, T Fiordi, M Dell'Omo, C Colangeli, A R Gabrielli, T Fabbri, A D'Alessandro.   

Abstract

This study, which was conducted in central Italy, included (a) 525 office workers employed in an air-conditioned building that had fan coil units in every room (building B) and (b) 281 subjects who worked in three naturally ventilated buildings (building A) that were operated by the same public administration. The prevalence of work-related symptoms was assessed by a questionnaire that was administered by an occupational medicine specialist. The most frequent complaints of employees in building B were dry air, strong lighting, and high temperature. Employees who worked in this building experienced a statistically higher prevalence of symptoms that were characteristic of the sick building syndrome. This is the first time that this syndrome has been reported in Italy. Excessive illumination, a low relative humidity, and fiberglass on floors and furniture might have contributed to the symptoms. Inadequate maintenance of the building's air-conditioning plant and the employees' lack of information regarding self-regulation of the fan coil units may also have contributed to the prevalence of symptoms.

Mesh:

Year:  1992        PMID: 1539998     DOI: 10.1080/00039896.1992.9935939

Source DB:  PubMed          Journal:  Arch Environ Health        ISSN: 0003-9896


  4 in total

1.  Building sickness syndrome in healthy and unhealthy buildings: an epidemiological and environmental assessment with cluster analysis.

Authors:  R M Niven; A M Fletcher; C A Pickering; E B Faragher; I N Potter; W B Booth; T J Jones; P D Potter
Journal:  Occup Environ Med       Date:  2000-09       Impact factor: 4.402

2.  Epidemiology of sick building syndrome and its associated risk factors in Singapore.

Authors:  P L Ooi; K T Goh; M H Phoon; S C Foo; H M Yap
Journal:  Occup Environ Med       Date:  1998-03       Impact factor: 4.402

3.  Automated cleaning of fan coil units with a natural detergent-disinfectant product.

Authors:  Giorgio Liguori; Maria Bagattini; Francesca Gallè; Mario Negrone; Valeria Di Onofrio; Maria Triassi
Journal:  Ann Clin Microbiol Antimicrob       Date:  2010-10-12       Impact factor: 3.944

4.  1998 equivalence of sensory responses to single and mixed volatile organic compounds at equimolar concentrations.

Authors:  J D Prah
Journal:  Environ Health Perspect       Date:  1998-11       Impact factor: 9.031