Low pulse oximeter-measured hemoglobin oxygen saturations with hemoglobin Cheverly.

R J Hohl1, A R Sherburne, J E Feeley, T H Huisman, C P Burns.   

Abstract

Unexpectedly low hemoglobin oxygen saturation as determined by pulse-oximeter analysis was observed in a patient who underwent an elective surgical procedure. Specific hemoglobin derivatives such as carboxyhemoglobin, methemoglobin, and reduced hemoglobin that have been described to lower pulse-oximetry determination of oxygenation were not detected. Absorbance spectra revealed the patient's hemoglobin to be different than that obtained from two normal volunteers. High-pressure liquid chromatographic analysis of the hemoglobin showed an unknown band that comprised 15% of the patient's hemoglobin. DNA sequence analysis showed a point mutation in the second nucleotide of the 45th codon of the beta-globin chain. This mutation encodes for an abnormal beta-chain (beta-45 Phe-->Ser) that has been described as hemoglobin Cheverly. Hemoglobin Cheverly is an unstable hemoglobin that has a similar mutation as the beta-42 Phe-->Ser mutation seen in hemoglobin Hammersmith. Hemoglobin Hammersmith and another unstable hemoglobin, hemoglobin Köln, have previously been described to have unexpectedly low pulse-oximeter-determined oxyhemoglobin levels. That we find hemoglobin Cheverly to result in a similar phenomenon suggests that pulse-oximeter monitoring of oxygenation status may not be appropriate for the unstable hemoglobins. Low pulse-oximeter oxygenation determinations for these hemoglobins do not appear to predict clinical hypoxemia.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9798654     DOI: 10.1002/(sici)1096-8652(199811)59:3<181::aid-ajh1>3.0.co;2-i

Source DB:  PubMed          Journal:  Am J Hematol        ISSN: 0361-8609            Impact factor:   10.047


  5 in total

Review 1.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

2.  Pulse oximetry and genetic hemoglobinopathies.

Authors:  S Mariette; S Leteurtre; A Lambilliotte; F Leclerc
Journal:  Intensive Care Med       Date:  2005-08-27       Impact factor: 17.440

3.  Validation of oxygen saturation monitoring in neonates.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou
Journal:  Am J Crit Care       Date:  2007-03       Impact factor: 2.228

4.  Case-control studies of novel hemoglobin anomalies as differential diagnosis in sleep apnea syndrome.

Authors:  Berndt Zur; Michael Ludwig; Birgit Stoffel-Wagner
Journal:  Sleep Breath       Date:  2012-05-13       Impact factor: 2.816

5.  Automated oxyhemoglobin dissociation curve construction to assess sickle cell anemia therapy.

Authors:  R C Young; R E Rachal; M Del Pilar Aguinaga; B L Nelson; B C Kim; W P Winter; O Castro
Journal:  J Natl Med Assoc       Date:  2000-09       Impact factor: 1.798

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.