Literature DB >> 17525983

Imaging mesial temporal lobe activation during scene encoding: comparison of fMRI using BOLD and arterial spin labeling.

María A Fernández-Seara1, Jiongjiong Wang, Ze Wang, Marc Korczykowski, Matthias Guenther, David A Feinberg, John A Detre.   

Abstract

Memory encoding is a critical brain function subserved by the hippocampus (HP) and mesial temporal lobe (mTL) structures. Visualization of mTL memory activation with BOLD fMRI is complicated by the presence of static susceptibility gradients in this region. Arterial spin labeled (ASL) perfusion fMRI offers an alternative approach not dependent on susceptibility contrast that instead suffers from lower intrinsic signal-to-noise ratio. An improved ASL perfusion fMRI approach combining pseudo-continuous ASL and a T(2)*-insensitive sequence (GRASE) with background suppression was compared to BOLD fMRI at 3 T during a scene encoding task known to activate the HP. Overall, an approximate sixfold sensitivity increase of ASL fMRI was achieved, with improved coverage in the anterior mTL, while suppression of the static tissue enhanced the stability of the ASL series by a factor of 2.4. Perfusion fMRI using this approach with 4 mm isotropic resolution yielded better localized and stronger group activation maps than BOLD fMRI at a standard resolution of 3 mm isotropic voxels. Increasing the resolution for BOLD to 2.5 mm isotropic produced stronger mTL and hippocampal activation in the group and individual subjects than the ASL technique, due to superior temporal resolution and reduced partial volume effects. Future improvements in ASL spatial and temporal resolution would allow the benefits of both approaches to be combined to further enhance the sensitivity for detecting mTL activation during memory encoding. (copyright) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17525983      PMCID: PMC6871282          DOI: 10.1002/hbm.20366

Source DB:  PubMed          Journal:  Hum Brain Mapp        ISSN: 1065-9471            Impact factor:   5.038


  36 in total

1.  Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling.

Authors:  J B Gonzalez-At; D C Alsop; J A Detre
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  An automated method for neuroanatomic and cytoarchitectonic atlas-based interrogation of fMRI data sets.

Authors:  Joseph A Maldjian; Paul J Laurienti; Robert A Kraft; Jonathan H Burdette
Journal:  Neuroimage       Date:  2003-07       Impact factor: 6.556

3.  Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla.

Authors:  Jiongjiong Wang; David C Alsop; Lin Li; John Listerud; Julio B Gonzalez-At; Mitchell D Schnall; John A Detre
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

4.  Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system.

Authors:  Luis Hernandez-Garcia; Gregory R Lee; Alberto L Vazquez; Douglas C Noll
Journal:  Magn Reson Med       Date:  2004-03       Impact factor: 4.668

5.  Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: feasibility study.

Authors:  Jiongjiong Wang; Yan Zhang; Ronald L Wolf; Anne C Roc; David C Alsop; John A Detre
Journal:  Radiology       Date:  2005-02-16       Impact factor: 11.105

6.  Making memories: brain activity that predicts how well visual experience will be remembered.

Authors:  J B Brewer; Z Zhao; J E Desmond; G H Glover; J D Gabrieli
Journal:  Science       Date:  1998-08-21       Impact factor: 47.728

7.  Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla.

Authors:  A Jesmanowicz; P A Bandettini; J S Hyde
Journal:  Magn Reson Med       Date:  1998-11       Impact factor: 4.668

8.  The hippocampal formation participates in novel picture encoding: evidence from functional magnetic resonance imaging.

Authors:  C E Stern; S Corkin; R G González; A R Guimaraes; J R Baker; P J Jennings; C A Carr; R M Sugiura; V Vedantham; B R Rosen
Journal:  Proc Natl Acad Sci U S A       Date:  1996-08-06       Impact factor: 11.205

9.  The benefits of increasing spatial resolution as a means of reducing artifacts due to field inhomogeneities.

Authors:  I R Young; I J Cox; D J Bryant; G M Bydder
Journal:  Magn Reson Imaging       Date:  1988 Sep-Oct       Impact factor: 2.546

10.  Assessment of relative brain iron concentrations using T2-weighted and T2*-weighted MRI at 3 Tesla.

Authors:  R J Ordidge; J M Gorell; J C Deniau; R A Knight; J A Helpern
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

View more
  18 in total

Review 1.  MRI studies in late-life mood disorders.

Authors:  Carmen Andreescu; Howard Aizenstein
Journal:  Curr Top Behav Neurosci       Date:  2012

2.  Application of whole-brain CBV-weighted fMRI to a cognitive stimulation paradigm: robust activation detection in a stroop task experiment using 3D GRASE VASO.

Authors:  Benedikt A Poser; David G Norris
Journal:  Hum Brain Mapp       Date:  2010-06-24       Impact factor: 5.038

3.  Arterial spin labeling in neuroimaging.

Authors:  Sasitorn Petcharunpaisan; Joana Ramalho; Mauricio Castillo
Journal:  World J Radiol       Date:  2010-10-28

Review 4.  Clinical neuroimaging using arterial spin-labeled perfusion magnetic resonance imaging.

Authors:  Ronald L Wolf; John A Detre
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

5.  Narrative speech production: an fMRI study using continuous arterial spin labeling.

Authors:  Vanessa Troiani; Maria A Fernández-Seara; Ze Wang; John A Detre; Sherry Ash; Murray Grossman
Journal:  Neuroimage       Date:  2007-12-15       Impact factor: 6.556

6.  Potentials and challenges for arterial spin labeling in pharmacological magnetic resonance imaging.

Authors:  Danny J J Wang; Yufen Chen; María A Fernández-Seara; John A Detre
Journal:  J Pharmacol Exp Ther       Date:  2011-02-11       Impact factor: 4.030

7.  Volumetric cerebral perfusion imaging in healthy adults: regional distribution, laterality, and repeatability of pulsed continuous arterial spin labeling (PCASL).

Authors:  Adolf Pfefferbaum; Sandra Chanraud; Anne-Lise Pitel; Ajit Shankaranarayanan; David C Alsop; Torsten Rohlfing; Edith V Sullivan
Journal:  Psychiatry Res       Date:  2010-05-20       Impact factor: 3.222

Review 8.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

Review 9.  Perfusion MRI: the five most frequently asked technical questions.

Authors:  Marco Essig; Mark S Shiroishi; Thanh Binh Nguyen; Marc Saake; James M Provenzale; David Enterline; Nicoletta Anzalone; Arnd Dörfler; Alex Rovira; Max Wintermark; Meng Law
Journal:  AJR Am J Roentgenol       Date:  2013-01       Impact factor: 3.959

10.  Differential age effects on cerebral blood flow and BOLD response to encoding: associations with cognition and stroke risk.

Authors:  Katherine J Bangen; Khaled Restom; Thomas T Liu; Amy J Jak; Christina E Wierenga; David P Salmon; Mark W Bondi
Journal:  Neurobiol Aging       Date:  2007-12-21       Impact factor: 4.673

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.