Literature DB >> 9790558

Radiation dosimetry for extremity radiographs.

W Huda1, N A Gkanatsios.   

Abstract

The energy imparted, epsilon, to a patient undergoing an extremity x-ray examination may be obtained from the dose-area product incident on the patient. Values of energy imparted can be subsequently converted into the corresponding effective dose, E, using an extremity specific E/epsilon ratio. In this study, an E/epsilon ratio of 3 mSv/J was used to convert values of energy imparted into the corresponding upper limit of adult effective doses for all types of extremity examinations. A modification factor, based on the patient mass, was employed to determine the corresponding extremity effective doses to pediatric patients undergoing extremity examinations. Representative clinical technique factors for six common extremity examinations (hand, forearm, elbow, ankle, tibia/fibula, knee) were used to determine the dose-area product and the corresponding values of energy imparted. For adult extremity x-ray examinations, values of energy imparted ranged from 55 microJ to 920 microJ, with the energy imparted to 1-y-old patients being a factor of about 20 lower. Upper limits of effective doses for adult extremity x-ray examinations ranged from 0.17 to 2.7 microSv, whereas the corresponding doses to 1-y-old patients were about a factor of three lower.

Entities:  

Mesh:

Year:  1998        PMID: 9790558     DOI: 10.1097/00004032-199811000-00005

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  13 in total

1.  Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects.

Authors:  Ambrose J Huang; Connie Y Chang; Bijoy J Thomas; Peter J MacMahon; William E Palmer
Journal:  Skeletal Radiol       Date:  2015-02-05       Impact factor: 2.199

Review 2.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

3.  Optimization of image quality and patient dose in radiographs of paediatric extremities using direct digital radiography.

Authors:  A Jones; C Ansell; C Jerrom; I D Honey
Journal:  Br J Radiol       Date:  2015-03-27       Impact factor: 3.039

4.  An implanted pH sensor read using radiography.

Authors:  Md Arifuzzaman; Paul W Millhouse; Yash Raval; Thomas B Pace; Caleb J Behrend; Shayesteh Beladi Behbahani; John D DesJardins; Tzuen-Rong J Tzeng; Jeffrey N Anker
Journal:  Analyst       Date:  2019-04-23       Impact factor: 4.616

5.  Mitteilungen der DGKFO.

Authors:  H Fischer-Brandies
Journal:  J Orofac Orthop       Date:  2016-07       Impact factor: 1.938

6.  The ankle meter: an instrument for evaluation of anterior talar drawer in ankle sprain.

Authors:  Gunter Spahn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-04-15       Impact factor: 4.342

Review 7.  Imaging of lower extremity stress fracture injuries.

Authors:  Daniel S Moran; Rachel K Evans; Eran Hadad
Journal:  Sports Med       Date:  2008       Impact factor: 11.136

8.  A paediatric bone index derived by automated radiogrammetry.

Authors:  H H Thodberg; R R van Rijn; T Tanaka; D D Martin; S Kreiborg
Journal:  Osteoporos Int       Date:  2009-11-24       Impact factor: 4.507

9.  Cone-Beam CT in diagnosis of scaphoid fractures.

Authors:  Rolf Edlund; Mikael Skorpil; Gunilla Lapidus; Jenny Bäcklund
Journal:  Skeletal Radiol       Date:  2015-11-12       Impact factor: 2.199

10.  Investigation of growth, development, and factors associated with injury in elite schoolboy footballers: prospective study.

Authors:  Amanda Johnson; Patrick Joseph Doherty; Anthony Freemont
Journal:  BMJ       Date:  2009-02-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.