Literature DB >> 9773890

Resolution of dimly fluorescent particles: a practical measure of fluorescence sensitivity.

E S Chase1, R A Hoffman.   

Abstract

Flow cytometry is usually used to analyze subpopulations of cells, not simply to measure the mean fluorescence level of a mixture. Thus, resolution or coefficient of variation (CV) of dimly stained populations is the most appropriate measure of fluorescence "sensitivity." Methods used to measure sensitivity that are in routine use do not unambiguously and completely determine the ability of a flow cytometer to resolve dimly fluorescent populations from each other. Since fluorescence sensitivity depends on two factors, background light (B) and detection efficiency (Q, the detected photoelectrons per fluorochrome molecule on an analyzed particle), one cannot uniquely define the operating condition of a flow cytometer with just one of these factors. In general, it is not possible to define the ability of a flow cytometer to resolve dim subpopulations by using a single number such as "noise level" or "detection threshold"-the description requires a "two-parameter" measure. A carefully characterized flow cytometer was used to determine the inherent fluorescent CV of dimly fluorescing beads. The fluorescence from the beads is also calibrated in terms of molecules of equivalent soluble fluorophore (MESF). The beads with known inherent CV and MESF provide a standard against which the instrument contribution to the CV of dim fluorescence can be measured. By measuring the standard deviation (SD) of the fluorescence histogram from unstained beads (noise) we obtain a second measure of instrument performance. The bead CV and noise SD are a sufficient pair of factors to determine the optical capability of a flow cytometer to resolve dim subpopulations of particles. It is also possible to use the measurements to calculate B and Q and use this information to predict the shapes of fluorescence histogram distributions of dim particles.

Mesh:

Substances:

Year:  1998        PMID: 9773890

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  17 in total

1.  Solid state yellow and orange lasers for flow cytometry.

Authors:  Veena Kapoor; Vladimir Karpov; Claudette Linton; Fedor V Subach; Vladislav V Verkhusha; William G Telford
Journal:  Cytometry A       Date:  2008-06       Impact factor: 4.355

2.  Quality assurance for polychromatic flow cytometry using a suite of calibration beads.

Authors:  Stephen P Perfetto; David Ambrozak; Richard Nguyen; Pratip K Chattopadhyay; Mario Roederer
Journal:  Nat Protoc       Date:  2012-11-08       Impact factor: 13.491

Review 3.  Spectral flow cytometry.

Authors:  John P Nolan; Danilo Condello
Journal:  Curr Protoc Cytom       Date:  2013-01

Review 4.  The intersection of flow cytometry with microfluidics and microfabrication.

Authors:  Menake E Piyasena; Steven W Graves
Journal:  Lab Chip       Date:  2014-03-21       Impact factor: 6.799

5.  Evaluating flow cytometer performance with weighted quadratic least squares analysis of LED and multi-level bead data.

Authors:  David R Parks; Faysal El Khettabi; Eric Chase; Robert A Hoffman; Stephen P Perfetto; Josef Spidlen; James C S Wood; Wayne A Moore; Ryan R Brinkman
Journal:  Cytometry A       Date:  2017-02-03       Impact factor: 4.355

Review 6.  Flow Cytometry: Impact on Early Drug Discovery.

Authors:  Bruce S Edwards; Larry A Sklar
Journal:  J Biomol Screen       Date:  2015-03-24

7.  Supercontinuum white light lasers for flow cytometry.

Authors:  William G Telford; Fedor V Subach; Vladislav V Verkhusha
Journal:  Cytometry A       Date:  2009-05       Impact factor: 4.355

8.  Green fiber lasers: an alternative to traditional DPSS green lasers for flow cytometry.

Authors:  William G Telford; Sergey A Babin; Serge V Khorev; Stephen H Rowe
Journal:  Cytometry A       Date:  2009-12       Impact factor: 4.355

9.  Visible and near infrared fluorescence spectral flow cytometry.

Authors:  John P Nolan; Danilo Condello; Erika Duggan; Mark Naivar; David Novo
Journal:  Cytometry A       Date:  2012-12-06       Impact factor: 4.355

10.  Enhanced red and near infrared detection in flow cytometry using avalanche photodiodes.

Authors:  William G Lawrence; Gyula Varadi; Gerald Entine; Edward Podniesinski; Paul K Wallace
Journal:  Cytometry A       Date:  2008-08       Impact factor: 4.355

View more