Literature DB >> 19072836

Supercontinuum white light lasers for flow cytometry.

William G Telford1, Fedor V Subach, Vladislav V Verkhusha.   

Abstract

Excitation of fluorescent probes for flow cytometry has traditionally been limited to a few discrete laser lines, an inherent limitation in our ability to excite the vast array of fluorescent probes available for cellular analysis. In this report, we have used a supercontinuum (SC) white light laser as an excitation source for flow cytometry. By selectively filtering the wavelength of interest, almost any laser wavelength in the visible spectrum can be separated and used for flow cytometric analysis. The white light lasers used in this study were integrated into a commercial flow cytometry platform, and a series of high-transmission bandpass filters used to select wavelength ranges from the blue (approximately 480 nm) to the long red (>700 nm). Cells labeled with a variety of fluorescent probes or expressing fluorescent proteins were then analyzed, in comparison with traditional lasers emitting at wavelengths similar to the filtered SC source. Based on a standard sensitivity metric, the white light laser bandwidths produced similar excitation levels to traditional lasers for a wide variety of fluorescent probes and expressible proteins. Sensitivity assessment using fluorescent bead arrays confirmed that the SC laser and traditional sources resulted in similar levels of detection sensitivity. Supercontinuum white light laser sources therefore have the potential to remove a significant barrier in flow cytometric analysis, namely the limitation of excitation wavelengths. Almost any visible wavelength range can be made available for excitation, allowing access to virtually any fluorescent probe, and permitting "fine-tuning" of excitation wavelength to particular probes. (c) 2008 International Society for Advancement of Cytometry.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19072836      PMCID: PMC2674127          DOI: 10.1002/cyto.a.20687

Source DB:  PubMed          Journal:  Cytometry A        ISSN: 1552-4922            Impact factor:   4.355


  22 in total

1.  Analysis of UV-excited fluorochromes by flow cytometry using near-ultraviolet laser diodes.

Authors:  William G Telford
Journal:  Cytometry A       Date:  2004-09       Impact factor: 4.355

Review 2.  The molecular properties and applications of Anthozoa fluorescent proteins and chromoproteins.

Authors:  Vladislav V Verkhusha; Konstantin A Lukyanov
Journal:  Nat Biotechnol       Date:  2004-03       Impact factor: 54.908

Review 3.  Fluorescent proteins as a toolkit for in vivo imaging.

Authors:  Dmitriy M Chudakov; Sergey Lukyanov; Konstantin A Lukyanov
Journal:  Trends Biotechnol       Date:  2005-11-02       Impact factor: 19.536

4.  Increased immunofluorescence sensitivity using 532 nm laser excitation.

Authors:  Stephen P Perfetto; Mario Roederer
Journal:  Cytometry A       Date:  2007-02       Impact factor: 4.355

5.  Supercontinuum generation in tapered fibers.

Authors:  T A Birks; W J Wadsworth; P S Russell
Journal:  Opt Lett       Date:  2000-10-01       Impact factor: 3.776

6.  Composite frequency comb spanning 0.4-2.4 microm from a phase-controlled femtosecond Ti:sapphire laser and synchronously pumped optical parametric oscillator.

Authors:  J H Sun; B J S Gale; D T Reid
Journal:  Opt Lett       Date:  2007-06-01       Impact factor: 3.776

7.  Bright far-red fluorescent protein for whole-body imaging.

Authors:  Dmitry Shcherbo; Ekaterina M Merzlyak; Tatiana V Chepurnykh; Arkady F Fradkov; Galina V Ermakova; Elena A Solovieva; Konstantin A Lukyanov; Ekaterina A Bogdanova; Andrey G Zaraisky; Sergey Lukyanov; Dmitriy M Chudakov
Journal:  Nat Methods       Date:  2007-08-26       Impact factor: 28.547

8.  Solid state yellow and orange lasers for flow cytometry.

Authors:  Veena Kapoor; Vladimir Karpov; Claudette Linton; Fedor V Subach; Vladislav V Verkhusha; William G Telford
Journal:  Cytometry A       Date:  2008-06       Impact factor: 4.355

9.  Violet laser diodes as light sources for cytometry.

Authors:  H M Shapiro; N G Perlmutter
Journal:  Cytometry       Date:  2001-06-01

10.  A white light confocal microscope for spectrally resolved multidimensional imaging.

Authors:  J H Frank; A D Elder; J Swartling; A R Venkitaraman; A D Jeyasekharan; C F Kaminski
Journal:  J Microsc       Date:  2007-09       Impact factor: 1.758

View more
  3 in total

1.  Guide to red fluorescent proteins and biosensors for flow cytometry.

Authors:  Kiryl D Piatkevich; Vladislav V Verkhusha
Journal:  Methods Cell Biol       Date:  2011       Impact factor: 1.441

2.  Directed molecular evolution to design advanced red fluorescent proteins.

Authors:  Fedor V Subach; Kiryl D Piatkevich; Vladislav V Verkhusha
Journal:  Nat Methods       Date:  2011-11-29       Impact factor: 28.547

3.  Experimental tools to study molecular recognition within the nanoparticle corona.

Authors:  Markita P Landry; Sebastian Kruss; Justin T Nelson; Gili Bisker; Nicole M Iverson; Nigel F Reuel; Michael S Strano
Journal:  Sensors (Basel)       Date:  2014-09-02       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.