Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads.

A E Epstein1, G N Kay, V J Plumb, S M Dailey, P G Anderson.   

Abstract

BACKGROUND: Although the effects of epicardial implantable cardioverter-defibrillator (ICD) leads on underlying cardiac tissue have been reported, the gross and microscopic changes associated with endocardial ICD leads are less well described. This study describes the gross and microscopic changes associated with endocardial ICD leads in humans. METHODS AND
RESULTS: The hearts from 8 patients were examined. At the time of ICD implantation, the patients' mean age was 47+/-11 years, and the left ventricular ejection fraction was 0.24+/-0.10. Four patients had ischemic heart disease, and 4 had dilated cardiomyopathy. Five hearts were examined after transplantation; 3, after death. The electrode-myocardial interfaces were characterized by intense endocardial fibrosis and were remarkably consistent. Each lead was encased by a ring of fibroelastic tissue, and there was fibrosis of the right ventricular myocardium adjacent to the leads. Fibrosis involved the tricuspid valve in 5 patients, and 1 had perforation of the valve by the lead. Microscopically, interstitial fibrosis was adjacent to each lead in the current path of ICD shocks. Acute cell injury was present only in the hearts that had received recent shocks.
CONCLUSIONS: The ICD electrode-myocardial interface is characterized by intense fibrosis. The fibrosis associated with endocardial ICD leads and the cumulative acute damage produced by defibrillation discharges may explain changes in the defibrillation and pacing thresholds and the difficulty of lead extraction that can be encountered with transvenous ICD systems.

Entities:  

Mesh:

Year:  1998        PMID: 9769305     DOI: 10.1161/01.cir.98.15.1517

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  25 in total

Review 1.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

2.  Myocardial stunning following defibrillation threshold testing.

Authors:  Michael Mollerus; Leslee Naslund
Journal:  J Interv Card Electrophysiol       Date:  2007-09-11       Impact factor: 1.900

Review 3.  Electrical Storm: Incidence, Prognosis and Therapy.

Authors:  Antonio Sagone
Journal:  J Atr Fibrillation       Date:  2015-12-31

4.  A novel indication for transvenous lead extraction: upgrading implantable cardioverter defibrillator systems.

Authors:  V J Korley; N Hallet; M Daoust; L M Epstein
Journal:  J Interv Card Electrophysiol       Date:  2000-10       Impact factor: 1.900

5.  Endovascular extraction techniques: Part 3: Results and indications in patients with an ICD.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-06       Impact factor: 2.380

Review 6.  ICD programming to reduce shocks and improve outcomes.

Authors:  Valentina Kutyifa; Wojciech Zareba; Arthur J Moss
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

7.  Pacing lead inserted via the subclavian artery caused acute coronary syndrome.

Authors:  Peter Nordbeck; Heiner Langenfeld; Axel Krein; Wolfgang R Bauer; Oliver Ritter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

8.  Acetylation mediates Cx43 reduction caused by electrical stimulation.

Authors:  Viviana Meraviglia; Valerio Azzimato; Claudia Colussi; Maria Cristina Florio; Anna Binda; Alice Panariti; Khaled Qanud; Silvia Suffredini; Laura Gennaccaro; Michele Miragoli; Andrea Barbuti; Paul D Lampe; Carlo Gaetano; Peter P Pramstaller; Maurizio C Capogrossi; Fabio A Recchia; Giulio Pompilio; Ilaria Rivolta; Alessandra Rossini
Journal:  J Mol Cell Cardiol       Date:  2015-08-08       Impact factor: 5.000

9.  Evolution of paced QRS and QTc intervals in children with epicardial pacing leads.

Authors:  Maren Tomaske; Paul Harpes; Rene Prêtre; Ali Dodge-Khatami; Urs Bauersfeld
Journal:  Clin Res Cardiol       Date:  2007-08-13       Impact factor: 5.460

10.  Extraction of defibrillator leads recalled for cable externalization and failure.

Authors:  Divyang Patel; Evan Adelstein; Jan Nemec; G Stuart Mendenhall; Raveen Bazaz; Sandeep Jain; Samir Saba
Journal:  J Interv Card Electrophysiol       Date:  2012-11-21       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.