Literature DB >> 9768897

Total knee arthroplasty with the PFC system. Results at a minimum of ten years and survivorship analysis.

P A Schai1, T S Thornhill, R D Scott.   

Abstract

A consecutive series of 235 total knee arthroplasties using the PFC system was followed prospectively for at least ten years in 186 patients. The operation was for osteoarthritis in 150 knees, for rheumatoid arthritis in 83, and for Paget's disease and femoral osteonecrosis in one knee each. At the latest review 56 patients had died, five were too ill to assess and three could not be traced. The PFC knee replacement utilised was a non-conforming posterior-cruciate-retaining prosthesis with a polyethylene insert which is flat in the sagittal plane. The patella was resurfaced using a metal-backed component in 170 cases, but later in the series we used an all-polyethylene component in 22 knees; 43 patellae were not resurfaced. The survival without need for reoperation for any reason was 90% at ten years. Nineteen revisions were component-related due to failure of nine metal-backed patellae, nine polyethylene inserts, and one unresurfaced patella; two reoperations were for synovectomy (one for recurrent haemarthrosis and one for recurrent rheumatoid synovitis) and three were for metastatic joint infection. There were no revisions for aseptic loosening of femoral or tibial components, or the all-polyethylene patellar replacement. The PFC system provides good and predictable results in tricompartmental arthritis of the knee. Loosening appeared to be negligible, but there were wear-related problems in 8%. The change from a metal-backed patella and an increase in the contact area of the tibial insert should provide further improvement by minimising wear.

Entities:  

Mesh:

Year:  1998        PMID: 9768897     DOI: 10.1302/0301-620x.80b5.8368

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  30 in total

1.  [Total knee arthroplasty--navigation as the standard].

Authors:  L Kinzl; F Gebhard; P Keppler
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

2.  A new high-flexion knee scoring system to eliminate the ceiling effect.

Authors:  Sang-Eun Na; Chul-Won Ha; Choong-Hee Lee
Journal:  Clin Orthop Relat Res       Date:  2011-11-29       Impact factor: 4.176

Review 3.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

4.  Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure?

Authors:  Ryan D Bauman; Derek R Johnson; Travis J Menge; Raymond H Kim; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

5.  Ten-year survival analysis of the PFC total knee arthroplasty--a surgeon's first 99 replacements.

Authors:  Alasdair J A Santini; Videsh Raut
Journal:  Int Orthop       Date:  2007-03-16       Impact factor: 3.075

6.  International multi-centre survivorship analysis of mobile bearing total knee arthroplasty.

Authors:  James B Stiehl; Karel J Hamelynck; Paul E Voorhorst
Journal:  Int Orthop       Date:  2006-03-18       Impact factor: 3.075

7.  Relationship between joint gap difference and range of motion in total knee arthroplasty: a prospective randomised study between different platforms.

Authors:  Hiroshi Higuchi; Kazuhisa Hatayama; Masaki Shimizu; Atsushi Kobayashi; Tsutomu Kobayashi; Kenji Takagishi
Journal:  Int Orthop       Date:  2009-04-28       Impact factor: 3.075

8.  A 5 to 8 year follow-up study of the Rotaglide mobile bearing total knee arthroplasty.

Authors:  Alastair Hudd; Kumar Kunasingam; David Ricketts; John Bush
Journal:  Int Orthop       Date:  2008-07-02       Impact factor: 3.075

9.  Intraoperative joint gaps affect postoperative range of motion in TKAs with posterior-stabilized prostheses.

Authors:  Toshifumi Watanabe; Takeshi Muneta; Ichiro Sekiya; Scott A Banks
Journal:  Clin Orthop Relat Res       Date:  2012-12-19       Impact factor: 4.176

10.  Unique relationship between osteophyte and femoral-tibia component size mismatch in determining polyethylene wear in primary total knee arthroplasty: a case report.

Authors:  Manjunath Ramappa; Andrew Port
Journal:  J Med Case Rep       Date:  2009-02-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.