Literature DB >> 9764440

Stabilometry and one-leg hop test have high test-retest reliability.

E Ageberg1, R Zätterström, U Moritz.   

Abstract

The purpose of this study was to investigate the reliability of repeated measurements and a possible learning or tiring process in single-limb stabilometry and one-leg hop test. An additional purpose was to study the correlation between different stabilometric variables. Seventy-five healthy subjects were examined twice with a median interval of 7 d, and with three consecutive measurements on each occasion. Single-limb stabilometry and one-leg hop test were found to have high reliability (ICC r = 0.68-0.83 and 0.96, respectively). The correlation between consecutive measurements was acceptable to high in stabilometry (r = 0.42-0.90, P = 0.002-P < 0.001) and high in the one-leg hop test (r = 0.91-0.97, P < 0.001). A learning process over time was observed. The correlation between the stabilometric variables was high (r = 0.73-0.95, P < 0.001).

Mesh:

Year:  1998        PMID: 9764440     DOI: 10.1111/j.1600-0838.1998.tb00192.x

Source DB:  PubMed          Journal:  Scand J Med Sci Sports        ISSN: 0905-7188            Impact factor:   4.221


  24 in total

1.  Examination of the Effectiveness of Predictors for Musculoskeletal Injuries in Female Soldiers.

Authors:  Einat Kodesh; Eyal Shargal; Rotem Kislev-Cohen; Shany Funk; Lev Dorfman; Gil Samuelly; Jay R Hoffman; Nurit Sharvit
Journal:  J Sports Sci Med       Date:  2015-08-11       Impact factor: 2.988

2.  A randomised, placebo controlled trial of low level laser therapy for activated Achilles tendinitis with microdialysis measurement of peritendinous prostaglandin E2 concentrations.

Authors:  J M Bjordal; R A B Lopes-Martins; V V Iversen
Journal:  Br J Sports Med       Date:  2006-01       Impact factor: 13.800

3.  Reliability and validity of a partial weight bearing measure of lower extremity performance.

Authors:  Daniel J Cipriani; Michelle Haines; Denise O'Rand; Susan Levy
Journal:  N Am J Sports Phys Ther       Date:  2009-05

4.  INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

Authors:  Leanne Sawle; Jennifer Freeman; Jonathan Marsden
Journal:  Int J Sports Phys Ther       Date:  2017-04

5.  Strength and functional symmetry is associated with post-operative rehabilitation in patients following anterior cruciate ligament reconstruction.

Authors:  Jay R Ebert; Peter Edwards; Luke Yi; Brendan Joss; Timothy Ackland; Richard Carey-Smith; Jens-Ulrich Buelow; Ben Hewitt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-09-15       Impact factor: 4.342

6.  The effect of prophylactic knee bracing on performance: balance, proprioception, coordination, and muscular power.

Authors:  Gul Baltaci; Gulcan Aktas; Elif Camci; Sevim Oksuz; Seda Yildiz; Tugce Kalaycioglu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-06       Impact factor: 4.342

7.  Ice-water immersion and delayed-onset muscle soreness: a randomised controlled trial.

Authors:  Kylie Louise Sellwood; Peter Brukner; David Williams; Alastair Nicol; Rana Hinman
Journal:  Br J Sports Med       Date:  2007-01-29       Impact factor: 13.800

8.  Reliability of fitness tests using methods and time periods common in sport and occupational management.

Authors:  Bryan D Burnstein; Russell J Steele; Ian Shrier
Journal:  J Athl Train       Date:  2011 Sep-Oct       Impact factor: 2.860

9.  Normalized motor function but impaired sensory function after unilateral non-reconstructed ACL injury: patients compared with uninjured controls.

Authors:  Eva Ageberg; Thomas Fridén
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-05       Impact factor: 4.342

10.  Principles of brain plasticity in improving sensorimotor function of the knee and leg in healthy subjects: a double-blind randomized exploratory trial.

Authors:  Eva Ageberg; Anders Björkman; Birgitta Rosén; Göran Lundborg; Ewa M Roos
Journal:  BMC Musculoskelet Disord       Date:  2009-08-05       Impact factor: 2.362

View more