Literature DB >> 9760365

Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study.

I Setz1, S H Lee, E Engel.   

Abstract

STATEMENT OF PROBLEM: Bar and stud attachments are widely used to stabilize overdentures on implants in the mandible. There is strong evidence that retention of the attachment is an important factor for a patient's satisfaction.
PURPOSE: This study describes retentive forces and wear of commercially available attachments of 4 implant systems (31, IMZ, Nobel Biocare, ITI Straumann) and 2 magnets (Steco).
METHODS: Forces while removing the keyway portion of an attachment in its path of insertion were measured with a platform load cell. A total of 15,000 removals were performed to simulate fatigue.
RESULTS: Retentive forces ranged between 3 and 85 N. The fatigue test revealed an initial increase of forces with some attachments. After 15,000 cycles, most of the attachments showed little loss of retention compared with the initial retentive forces. It is suggested that conventional fatigue tests with application of axial loads do no simulate clinical fatigue adequately.

Entities:  

Mesh:

Year:  1998        PMID: 9760365     DOI: 10.1016/s0022-3913(98)70133-7

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  16 in total

1.  An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

Authors:  Abdalbseet A Fatalla; Ke Song; Tianfeng Du; Yingguang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

2.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

3.  New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space.

Authors:  Abdalbseet A Fatalla; Ke Song; Ying-Guang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

4.  Wear of double crown systems: electroplated vs. casted female part.

Authors:  Stefan Bayer; Dominik Kraus; Ludger Keilig; Lina Gölz; Helmut Stark; Norbert Enkling
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

Review 5.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

6.  The effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures.

Authors:  Farhad Tabatabaian; Abolfazl Saboury; Zahra Sadat Sobhani; Vicki C Petropoulos
Journal:  J Dent (Tehran)       Date:  2014-09-30

7.  A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study.

Authors:  Namrata Agrawal; Sumeet Jain; Deepak Agrawal
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

8.  Comparison of changes in retentive force of three stud attachments for implant overdentures.

Authors:  Su-Min Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

9.  Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study.

Authors:  Carlos Aroso; Antonio Sergio Silva; Raul Ustrell; Jose Manuel Mendes; Ana Cristina Braga; Esther Berastegui; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

10.  Effect of bar cross-section and female housing material on retention of mandibular implant bar overdentures: A comparative in vitro study.

Authors:  Elsayed A Abdel-Khalek; Abdullah M Ibrahim
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.