Literature DB >> 9738367

[Low-dose computerized tomography of the jaw bone in pre-implantation diagnosis. Limits of dose reduction and accuracy of distance measurements].

S Hassfeld1, S Streib, H Sahl, U Stratmann, D Fehrentz, J Zöller.   

Abstract

Absorbed radiation doses delivered by computed tomography and panoramic radiography were measured in 16 anatomic sites using a head and neck phantom and thermoluminescent dosimetry. The recommended kilovoltage and scan time for dental scanning was reduced step by step, rating the quality of the low-dose scans. A reduction of up to 76% could be achieved without loss of diagnostic accuracy. Measured absorbed radiation dose ranges from 0.30 mGy (thyroid) to 29 mGy (skin) at 187.5 mAs and 1.0 mm-slices (25 mm scanning distance for maxilla, 30 mm for mandible). After reduction to 45 mAs, 0.07 mGy (thyroid) to 6.9 mGy (skin) was measured. Distance measurements on human jaw specimens were compared with corresponding CT image measurements. Average deviation was 0.1-0.3 mm. A dose reduction of 75% had no effect on the results. However, the doses of CT-scans reduced by 76% exceed by an average factor of 10 the doses of conventional panoramic radiography. Therefore, CT should be reserved for the planning of complex implant treatment in the direct vicinity of the maxillar sinus and nerves and for multiple implant insertion.

Entities:  

Mesh:

Year:  1998        PMID: 9738367     DOI: 10.1007/s100060050057

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  6 in total

1.  High-resolution CT of transplanted teeth: imaging technique and measurement accuracy.

Authors:  André Gahleitner; Ulrike Kuchler; Peter Homolka; Janina Heschl; Georg Watzek; Herwig Imhof
Journal:  Eur Radiol       Date:  2008-08-09       Impact factor: 5.315

2.  A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition.

Authors:  Mayur S Bhattad; Sudhindra Baliga; Pavan Vibhute
Journal:  Dental Press J Orthod       Date:  2015 Mar-Apr

3.  [Preoperative determination of the position of mandibular canal for planning sagittal ramus osteotomy of the mandible].

Authors:  E Pilling; M Schneider; R Mai; U Eckelt
Journal:  Mund Kiefer Gesichtschir       Date:  2003-12-16

4.  Potentials of ultrasound in the diagnosis of midfacial fractures*.

Authors:  R E Friedrich; M Heiland; S Bartel-Friedrich
Journal:  Clin Oral Investig       Date:  2003-09-30       Impact factor: 3.573

5.  [Sonography as a training tool for screening of dubious midfacial fractures].

Authors:  M Heiland; M Lenard; R Schmelzle; R E Friedrich
Journal:  Mund Kiefer Gesichtschir       Date:  2004-03-10

6.  Low-dose protocol of the spiral CT in orthodontics: comparative evaluation of entrance skin dose with traditional X-ray techniques.

Authors:  Giancarlo Cordasco; Marco Portelli; Angela Militi; Riccardo Nucera; Antonino Lo Giudice; Elda Gatto; Alessandra Lucchese
Journal:  Prog Orthod       Date:  2013-09-10       Impact factor: 2.750

  6 in total