Literature DB >> 9727952

Reduced circular field-of-view imaging.

K Scheffler1, J Hennig.   

Abstract

A rapid dynamic imaging technique based on polar k-space sampling is presented. A gain in temporal resolution is achieved by angular undersampling. A detailed analysis of the point spread function of angular undersampled polar imaging reveals a reduced diameter of the corresponding circular field of view. Under the assumption that dynamic changes are restricted to a local circular field of view, angular undersampled dynamic imaging allows the recording of rapid changes at high temporal and spatial resolution. The theoretical and experimental details of the technique are presented.

Mesh:

Year:  1998        PMID: 9727952     DOI: 10.1002/mrm.1910400319

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

1.  Myocardial wall tagging with undersampled projection reconstruction.

Authors:  D C Peters; F H Epstein; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

Review 2.  Real-time magnetic resonance imaging of cardiac function and flow-recent progress.

Authors:  Shuo Zhang; Arun A Joseph; Dirk Voit; Sebastian Schaetz; Klaus-Dietmar Merboldt; Christina Unterberg-Buchwald; Anja Hennemuth; Joachim Lotz; Jens Frahm
Journal:  Quant Imaging Med Surg       Date:  2014-10

3.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view.

Authors:  Dana C Peters; Michael A Guttman; Alexander J Dick; Venkatesh K Raman; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

5.  Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI.

Authors:  Andrew C Larson; Peter Kellman; Andrew Arai; Glenn A Hirsch; Elliot McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

6.  Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging.

Authors:  Peder E Z Larson; Steven M Conolly; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

7.  4D radial contrast-enhanced MR angiography with sliding subtraction.

Authors:  Ty A Cashen; Hyun Jeong; Maulin K Shah; Hem M Bhatt; Wanyong Shin; James C Carr; Matthew T Walker; H Hunt Batjer; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

Review 8.  Measurement techniques for magnetic resonance imaging of fast relaxing nuclei.

Authors:  Simon Konstandin; Armin M Nagel
Journal:  MAGMA       Date:  2013-07-24       Impact factor: 2.310

9.  High-resolution variable-density 3D cones coronary MRA.

Authors:  Nii Okai Addy; R Reeve Ingle; Holden H Wu; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2015-07-14       Impact factor: 4.668

10.  Radial sliding-window magnetic resonance angiography (MRA) with highly-constrained projection reconstruction (HYPR).

Authors:  Hyun J Jeong; Ty A Cashen; Michael C Hurley; Christopher Eddleman; Christopher Getch; H Hunt Batjer; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.