Literature DB >> 9727940

Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

D M Spielman1, E Adalsteinsson, K O Lim.   

Abstract

Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performed using linear shim correction terms, and although many scanners are also equipped with additional resistive shim supplies that can provide second and third-order shim fields, they are often not used due to the additional effort and scan time required. The question as to how much improvement can be achieved using additional higher-order shims compared with the linear shims alone was quantitatively addressed. Performance measures for both intervoxel B0 uniformity and intravoxel T2* line broadening were evaluated for 15 normal volunteers. The analysis tools developed in this study, along with the summarized data, can be useful in deciding if a given application warrants the additional time, effort, and expense (if additional hardware needs to be purchased) of implementing higher-order shimming routines. For CSI studies of the brain, the use of the higher-order shims, compared with linear terms alone, yielded approximately 30% greater volume of brain tissue that could be shimmed within typical constraints for intervoxel B0 shifts and intravoxel T2* linebroadening. In addition, a regional analysis shows significant improvement in the homogeneity within specific areas of the brain, particularly those near the skull.

Mesh:

Year:  1998        PMID: 9727940     DOI: 10.1002/mrm.1910400307

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Peak-specific phase correction for automated spectrum processing of in vivo magnetic resonance spectroscopic imaging by using the multiscale approach.

Authors:  Xiaodong Zhang; Xiaoping Hu
Journal:  Bo Pu Xue Za Zhi       Date:  2014-03-05

2.  The role of the human ventral premotor cortex in counting successive stimuli.

Authors:  Kenji Kansaku; Benjamin Carver; Ari Johnson; Keiji Matsuda; Norihiro Sadato; Mark Hallett
Journal:  Exp Brain Res       Date:  2006-10-19       Impact factor: 1.972

3.  Altered brain function underlying verbal memory encoding and retrieval in psychotic major depression.

Authors:  Ryan Kelley; Amy Garrett; Jeremy Cohen; Rowena Gomez; Anna Lembke; Jennifer Keller; Allan L Reiss; Alan Schatzberg
Journal:  Psychiatry Res       Date:  2012-11-11       Impact factor: 3.222

4.  Dynamic Shimming of the Human Brain at 7 Tesla.

Authors:  Christoph Juchem; Terence W Nixon; Piotr Diduch; Douglas L Rothman; Piotr Starewicz; Robin A de Graaf
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-07-06       Impact factor: 1.176

5.  Non-contrast-enhanced renal and abdominal MR angiography using velocity-selective inversion preparation.

Authors:  Taehoon Shin; Pauline W Worters; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2012-06-18       Impact factor: 4.668

Review 6.  In vivo B0 field shimming methods for MRI at 7T.

Authors:  Jason P Stockmann; Lawrence L Wald
Journal:  Neuroimage       Date:  2017-06-07       Impact factor: 6.556

7.  Multivendor implementation and comparison of volumetric whole-brain echo-planar MR spectroscopic imaging.

Authors:  Mohammad Sabati; Sulaiman Sheriff; Meng Gu; Juan Wei; Henry Zhu; Peter B Barker; Daniel M Spielman; Jeffry R Alger; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2014-10-29       Impact factor: 4.668

Review 8.  Gradient and shim technologies for ultra high field MRI.

Authors:  Simone A Winkler; Franz Schmitt; Hermann Landes; Joshua de Bever; Trevor Wade; Andrew Alejski; Brian K Rutt
Journal:  Neuroimage       Date:  2016-11-30       Impact factor: 6.556

Review 9.  Methodological consensus on clinical proton MRS of the brain: Review and recommendations.

Authors:  Martin Wilson; Ovidiu Andronesi; Peter B Barker; Robert Bartha; Alberto Bizzi; Patrick J Bolan; Kevin M Brindle; In-Young Choi; Cristina Cudalbu; Ulrike Dydak; Uzay E Emir; Ramon G Gonzalez; Stephan Gruber; Rolf Gruetter; Rakesh K Gupta; Arend Heerschap; Anke Henning; Hoby P Hetherington; Petra S Huppi; Ralph E Hurd; Kejal Kantarci; Risto A Kauppinen; Dennis W J Klomp; Roland Kreis; Marijn J Kruiskamp; Martin O Leach; Alexander P Lin; Peter R Luijten; Małgorzata Marjańska; Andrew A Maudsley; Dieter J Meyerhoff; Carolyn E Mountford; Paul G Mullins; James B Murdoch; Sarah J Nelson; Ralph Noeske; Gülin Öz; Julie W Pan; Andrew C Peet; Harish Poptani; Stefan Posse; Eva-Maria Ratai; Nouha Salibi; Tom W J Scheenen; Ian C P Smith; Brian J Soher; Ivan Tkáč; Daniel B Vigneron; Franklyn A Howe
Journal:  Magn Reson Med       Date:  2019-03-28       Impact factor: 4.668

10.  Regional myo-inositol concentration in mild cognitive impairment Using 1H magnetic resonance spectroscopic imaging.

Authors:  Małgorzata Siger; Norbert Schuff; Xiaoping Zhu; Bruce L Miller; Michael W Weiner
Journal:  Alzheimer Dis Assoc Disord       Date:  2009 Jan-Mar       Impact factor: 2.703

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.