Martin Wilson1, Ovidiu Andronesi2, Peter B Barker3, Robert Bartha4, Alberto Bizzi5, Patrick J Bolan6, Kevin M Brindle7, In-Young Choi8, Cristina Cudalbu9, Ulrike Dydak10, Uzay E Emir10, Ramon G Gonzalez11, Stephan Gruber12, Rolf Gruetter13, Rakesh K Gupta14, Arend Heerschap15, Anke Henning16, Hoby P Hetherington17, Petra S Huppi18, Ralph E Hurd19, Kejal Kantarci20, Risto A Kauppinen21, Dennis W J Klomp22, Roland Kreis23, Marijn J Kruiskamp24, Martin O Leach25, Alexander P Lin26, Peter R Luijten22, Małgorzata Marjańska6, Andrew A Maudsley27, Dieter J Meyerhoff28, Carolyn E Mountford29, Paul G Mullins30, James B Murdoch31, Sarah J Nelson32, Ralph Noeske33, Gülin Öz6, Julie W Pan34, Andrew C Peet35, Harish Poptani36, Stefan Posse37, Eva-Maria Ratai2, Nouha Salibi38, Tom W J Scheenen15, Ian C P Smith39, Brian J Soher40, Ivan Tkáč6, Daniel B Vigneron32, Franklyn A Howe41.
Abstract
Proton MRS (1 H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi-adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0 ) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.Entities:
Keywords: MRS; brain; consensus; metabolites; semi-LASER; shimming
Mesh:
Substances:
Year: 2019 PMID: 30919510 PMCID: PMC7179569 DOI: 10.1002/mrm.27742
Source DB: PubMed Journal: Magn Reson Med ISSN: 0740-3194 Impact factor: 4.668