Literature DB >> 9726477

MR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils.

F Gönner1, O Heid, L Remonda, G Nicoli, R W Baumgartner, N Godoy, G Schroth.   

Abstract

We evaluated a time-of-flight three-dimensional MR angiographic sequence with an ultrashort echo time for its ability to characterize the perfusional state of cerebral aneurysms that had been treated with Guglielmi detachable coils and to depict adjacent cerebral arteries. The results were compared with findings at conventional MR angiography and digital subtraction angiography. Adjacent vessels were seen better in 36% of patients imaged with the new technique. Both MR angiographic methods detected residual cerebral aneurysmal perfusion with a tendency to overestimate the patent portion of the aneurysm.

Entities:  

Mesh:

Year:  1998        PMID: 9726477      PMCID: PMC8332223     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  35 in total

Review 1.  Interventional neuroradiology.

Authors:  C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2000-01       Impact factor: 3.825

2.  MR angiographic evaluation of platinum coil packs at 1.5T and 3T: an in vitro assessment of artifact production: technical note.

Authors:  Matthew T Walker; Jerome Tsai; Todd Parish; Brian Tzung; Ali Shaibani; Elizabeth Krupinski; Eric J Russell
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

Review 3.  Modern cross-sectional imaging in the diagnosis and follow-up of intracranial aneurysms.

Authors:  Karsten Papke; Friedhelm Brassel
Journal:  Eur Radiol       Date:  2006-01-14       Impact factor: 5.315

Review 4.  MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis.

Authors:  Thomas C Kwee; Robert M Kwee
Journal:  Neuroradiology       Date:  2007-07-24       Impact factor: 2.804

Review 5.  MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis.

Authors:  M J van Amerongen; H D Boogaarts; J de Vries; A L M Verbeek; F J A Meijer; M Prokop; R H M A Bartels
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-05       Impact factor: 3.825

6.  A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms.

Authors:  T J Kaufmann; J Huston; H J Cloft; J Mandrekar; L Gray; M A Bernstein; J L Atkinson; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-17       Impact factor: 3.825

Review 7.  Noninvasive imaging of treated cerebral aneurysms, part I: MR angiographic follow-up of coiled aneurysms.

Authors:  R C Wallace; J P Karis; S Partovi; D Fiorella
Journal:  AJNR Am J Neuroradiol       Date:  2007 Jun-Jul       Impact factor: 3.825

8.  Aneurysms of the anterior communicating artery treated with Guglielmi detachable coils: follow-up with contrast-enhanced MR angiography.

Authors:  Xavier Leclerc; Jean-François Navez; Jean-Yves Gauvrit; Jean-Paul Lejeune; Jean-Pierre Pruvo
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

9.  Three-dimensional time-of-flight MR angiography for evaluation of intracranial aneurysms after endosaccular packing with Guglielmi detachable coils: comparison with 3D digital subtraction angiography.

Authors:  Mika Okahara; Hiro Kiyosue; Yuzo Hori; Masanori Yamashita; Hirofumi Nagatomi; Hiromu Mori
Journal:  Eur Radiol       Date:  2004-04-21       Impact factor: 5.315

10.  Intracranial aneurysms treated with Guglielmi detachable coils: is contrast material necessary in the follow-up with 3D time-of-flight MR angiography?

Authors:  Jean-Philippe Cottier; Aurore Bleuzen-Couthon; Sophie Gallas; Catherine B Vinikoff-Sonier; Philippe Bertrand; Florence Domengie; Laurent Barantin; Denis Herbreteau
Journal:  AJNR Am J Neuroradiol       Date:  2003-10       Impact factor: 3.825

View more