Literature DB >> 17646977

MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis.

Thomas C Kwee1, Robert M Kwee.   

Abstract

INTRODUCTION: The aim of this study was to systematically review published data on the diagnostic performance of magnetic resonance angiography (MRA) compared with digital subtraction angiography as reference standard in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils.
METHODS: A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Two reviewers independently assessed the methodological quality of each study. A meta-analysis of the reported sensitivity and specificity of each study was performed.
RESULTS: The inclusion criteria were met by 16 studies. The studies had moderate methodological quality. Pooled sensitivity and specificity of non-enhanced time-of-flight MRA (TOF-MRA) for the detection of residual flow (within the aneurysmal neck and/or coil mesh) were 83.3% (95% CI 70.3-91.3%) and 90.6% (95% CI 80.4-95.8%), respectively. Pooled sensitivity and specificity of contrast-enhanced MRA (CE-MRA) for the detection of residual flow were 86.8% (95% CI 71.4-94.5%) and 91.9% (95% CI 79.8-97.0%), respectively. All pooled estimates were subject to heterogeneity. There were no statistically significant differences in pooled sensitivity and specificity between TOF-MRA and CE-MRA.
CONCLUSION: The results of this study suggest that both TOF-MRA and CE-MRA achieve a moderate to high diagnostic performance. However, the findings should be interpreted with caution because the included studies were of moderate methodological quality and all pooled estimates were subject to heterogeneity. More well-designed studies are required to confirm the current results and MRA at higher field strength (>1.5 T) needs to be further explored.

Entities:  

Mesh:

Year:  2007        PMID: 17646977     DOI: 10.1007/s00234-007-0266-5

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  56 in total

Review 1.  MR angiography of the intracranial vessels: technical aspects and clinical applications.

Authors:  Ozkan Ozsarlak; Johan W Van Goethem; Menno Maes; Paul M Parizel
Journal:  Neuroradiology       Date:  2004-12-04       Impact factor: 2.804

2.  Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils.

Authors:  L Brunereau; J P Cottier; C B Sonier; B Medioni; P Bertrand; P Rouleau; D Sirinelli; D Herbreteau
Journal:  J Comput Assist Tomogr       Date:  1999 Mar-Apr       Impact factor: 1.826

3.  A multicenter study of 705 ruptured intracranial aneurysms treated with Guglielmi detachable coils.

Authors:  Sophie Gallas; Anne Pasco; Jean-Philippe Cottier; Jean Gabrillargues; Jacques Drouineau; Christophe Cognard; Denis Herbreteau
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

4.  MR angiography at 3T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils.

Authors:  Charles B L M Majoie; Marieke E Sprengers; Willem Jan J van Rooij; Cristina Lavini; Menno Sluzewski; Jeroen C van Rijn; Gerard J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

5.  Three-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils.

Authors:  N Anzalone; C Righi; F Simionato; F Scomazzoni; G Pagani; G Calori; P Santino; G Scotti
Journal:  AJNR Am J Neuroradiol       Date:  2000-04       Impact factor: 3.825

6.  Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: Electrochemical basis, technique, and experimental results.

Authors:  G Guglielmi; F Viñuela; I Sepetka; V Macellari
Journal:  J Neurosurg       Date:  1991-07       Impact factor: 5.115

7.  Endovascular treatment of unruptured aneurysms.

Authors:  D Roy; G Milot; J Raymond
Journal:  Stroke       Date:  2001-09       Impact factor: 7.914

8.  Prevalence and risk of rupture of intracranial aneurysms: a systematic review.

Authors:  G J Rinkel; M Djibuti; A Algra; J van Gijn
Journal:  Stroke       Date:  1998-01       Impact factor: 7.914

9.  Time-of-flight MR angiography targeted to coiled intracranial aneurysms is more sensitive to residual flow than is digital subtraction angiography.

Authors:  Naoaki Yamada; Katsuhiko Hayashi; Kenichi Murao; Masahiro Higashi; Koji Iihara
Journal:  AJNR Am J Neuroradiol       Date:  2004-08       Impact factor: 3.825

10.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

View more
  28 in total

1.  Evaluation of meglumine gadoterate-enhanced MR angiography (MRA) compared with time-of-flight MRA in the diagnosis of clinically significant non-coronary arterial disease: a pooled analysis of data from two clinical trials.

Authors:  D J Shah; T-H Lim
Journal:  Br J Radiol       Date:  2011-12-13       Impact factor: 3.039

2.  Evidence-based neuroradiology: a necessity.

Authors:  Philippe Demaerel
Journal:  Neuroradiology       Date:  2007-07-10       Impact factor: 2.804

3.  Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA.

Authors:  Birgitta Ramgren; Roger Siemund; Mats Cronqvist; Per Undrén; Ola G Nilsson; Stig Holtås; Elna-Marie Larsson
Journal:  Neuroradiology       Date:  2008-08-21       Impact factor: 2.804

Review 4.  MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis.

Authors:  M J van Amerongen; H D Boogaarts; J de Vries; A L M Verbeek; F J A Meijer; M Prokop; R H M A Bartels
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-05       Impact factor: 3.825

5.  A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms.

Authors:  T J Kaufmann; J Huston; H J Cloft; J Mandrekar; L Gray; M A Bernstein; J L Atkinson; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-17       Impact factor: 3.825

Review 6.  Review of 2 decades of aneurysm-recurrence literature, part 2: Managing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

7.  The clinical value of ceMRA versus DSA for follow-up of intracranial aneurysms treated by coil embolization: an assessment of occlusion classifications and impact on treatment decisions.

Authors:  Maximilian Patzig; Robert Forbrig; Margaretha Gruber; Thomas Liebig; Franziska Dorn
Journal:  Eur Radiol       Date:  2020-11-21       Impact factor: 5.315

8.  Will Fluoroscopic Follow-up after Stent-Assisted Coiling of Cerebral Aneurysms Provide Information on Recanalization?

Authors:  Hyun Ho Oh; Cheolkyu Jung; Tae Hong Lee; Bae Ju Kwon; Young Kim; Kyu Chang Lee
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

9.  Contrast-enhanced time-resolved MRA for follow-up of intracranial aneurysms treated with the pipeline embolization device.

Authors:  S R Boddu; F C Tong; S Dehkharghani; J E Dion; A M Saindane
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-03       Impact factor: 3.825

10.  New technique: the use of the THRIVE sequence in the follow-up of patients who received endovascular intracranial aneurysm treatment.

Authors:  Emre Mırçık; Bahattin Hakyemez
Journal:  Neuroradiology       Date:  2020-09-11       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.