Literature DB >> 9725936

Laboratory investigation of the mass stability of sampling cassettes from inhalable aerosol samplers.

J P Smith1, D L Bartley, E R Kennedy.   

Abstract

A study was conducted to evaluate the mass stability of the materials used in the construction of samplers with internal cassettes for the gravimetric measurement of inhalable aerosol exposures. The internal cassettes from IOM samplers were studied. Results indicate that the mass stability of filters is uniform, but the mass stability of the cassette material may dramatically affect the results of the measurement. Cassettes constructed from plastic exhibited drastic shifts in mass depending on the environmental conditions of their storage. Under room humidity, the plastic cassettes absorbed 1 to 2 mg of water over several days. When these cassettes were placed in a desiccator, they lost mass consistently but did not approach a stable mass. Studies repeated with cassettes made of stainless steel showed negligible mass variability. Based on this study, the use of stainless steel cassettes is recommended for gravimetric determinations of aerosol exposure, although field blanks may in some cases be used for correction of data from plastic cassettes. This study shows the need to evaluate the mass stability of the cassette material of any sampling device where an internal cassette is weighed together with the filter.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9725936     DOI: 10.1080/15428119891010767

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  3 in total

1.  Field comparison of inhalable aerosol samplers applied in the european rubber manufacturing industry.

Authors:  Frank de Vocht; Daan Huizer; Maarten Prause; Kristina Jakobsson; Beata Peplonska; Kurt Straif; Hans Kromhout
Journal:  Int Arch Occup Environ Health       Date:  2006-02-28       Impact factor: 3.015

2.  Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules.

Authors:  Sean O'Connor; Paula Fey O'Connor; H Amy Feng; Kevin Ashley
Journal:  Gefahrst Reinhalt Luft       Date:  2014-10       Impact factor: 0.323

3.  A field evaluation of a single sampler for respirable and inhalable indium and dust measurements at an indium-tin oxide manufacturing facility.

Authors:  Brie Hawley Blackley; Jenna L Gibbs; Kristin J Cummings; Aleksandr B Stefaniak; Ji Young Park; Marcia Stanton; M Abbas Virji
Journal:  J Occup Environ Hyg       Date:  2019-01-28       Impact factor: 2.155

  3 in total