Literature DB >> 9719968

High precision biometry of pseudophakic eyes using partial coherence interferometry.

O Findl1, W Drexler, R Menapace, C K Hitzenberger, A F Fercher.   

Abstract

PURPOSE: To investigate the applicability of the scanning version of dual-beam partial coherence interferometry (PCI) for measuring the anterior segment and axial length of pseudophakic eyes in a clinical setting and to determine the achievable precision with this biometry technique.
SETTING: Department of Ophthalmology, Vienna General Hospital, and Institute of Medical Physics, University of Vienna, Austria.
METHODS: Partial coherence interferometry was performed in 39 pseudophakic eyes of 39 patients after implantation of a foldable acrylic intraocular lens (IOL).
RESULTS: Effective lens position (ELP), IOL thickness and lens-capsule distance (LCD) were determined with a precision of 2 to 3 microns; corneal thickness and axial eye length, with a precision of 0.8 and 5.0 microns, respectively. The mean ELP of the IOL was 4.093 mm +/- 0.290 (SD). In 7 eyes (18%), a positive LCD of 68 +/- 40 microns was detected with PCI. Mean corneal thickness was 526.4 +/- 31.5 microns; mean IOL thickness, 791.5 +/- 40.2 microns; and mean axial length, 23.388 +/- 0.824 mm.
CONCLUSION: The scanning version of PCI enables high precision (< or = 5 microns) and high resolution (approximately 12 microns) biometry of pseudophakic eyes that is better than conventional ultrasound by a factor of more than 20. For the first time, positive LCD, a possible risk factor for posterior capsule opacification, could be detected and quantified. Furthermore, this technique offers a high degree of comfort for the patient since it is a noncontact method with no need for local anesthesia or pupil dilation and has a reduced risk of corneal infection.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9719968     DOI: 10.1016/s0886-3350(98)80102-8

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  15 in total

Review 1.  Accommodating intraocular lenses: a critical review of present and future concepts.

Authors:  R Menapace; O Findl; K Kriechbaum; Ch Leydolt-Koeppl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-08-30       Impact factor: 3.117

2.  Effects of combined cataract surgery and trabeculectomy with mitomycin C on ocular dimensions.

Authors:  S K Law; A M Mansury; D Vasudev; J Caprioli
Journal:  Br J Ophthalmol       Date:  2005-08       Impact factor: 4.638

3.  Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes.

Authors:  Matthias Bolz; Ana Prinz; Wolfgang Drexler; Oliver Findl
Journal:  Br J Ophthalmol       Date:  2006-10-18       Impact factor: 4.638

4.  Changes in axial length following trabeculectomy and glaucoma drainage device surgery.

Authors:  B A Francis; M Wang; H Lei; L T Du; D S Minckler; R L Green; C Roland
Journal:  Br J Ophthalmol       Date:  2005-01       Impact factor: 4.638

5.  Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry.

Authors:  Mohammad Soleimani; Hassan Hashemi; Shiva Mehravaran; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

6.  [Precision of a new device for biometric measurements in pseudophakic eyes].

Authors:  A L Hildebrandt; G U Auffarth; M P Holzer
Journal:  Ophthalmologe       Date:  2011-08       Impact factor: 1.059

7.  Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode.

Authors:  B Meinhardt; O Stachs; J Stave; R Beck; R Guthoff
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-09-15       Impact factor: 3.117

8.  Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography.

Authors:  Raghavan Lavanya; Livia Teo; David S Friedman; Han T Aung; Mani Baskaran; Hong Gao; Tamuno Alfred; Steve K Seah; Kenji Kashiwagi; Paul J Foster; Tin Aung
Journal:  Br J Ophthalmol       Date:  2007-02-27       Impact factor: 4.638

9.  Surgical management of presbyopia.

Authors:  André Am Torricelli; Jackson B Junior; Marcony R Santhiago; Samir J Bechara
Journal:  Clin Ophthalmol       Date:  2012-09-06

10.  Intraocular lens power calculation using IOLMaster and various formulas in short eyes.

Authors:  Young Rae Roh; Sang Mok Lee; Young Keun Han; Mee Kum Kim; Won Ryang Wee; Jin Hak Lee
Journal:  Korean J Ophthalmol       Date:  2011-05-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.