Literature DB >> 9719108

Computed tomographic simulation of craniospinal fields in pediatric patients: improved treatment accuracy and patient comfort.

K Mah1, C E Danjoux, S Manship, N Makhani, M Cardoso, K E Sixel.   

Abstract

PURPOSE: To reduce the time required for planning and simulating craniospinal fields through the use of a computed tomography (CT) simulator and virtual simulation, and to improve the accuracy of field and shielding placement. METHODS AND MATERIALS: A CT simulation planning technique was developed. Localization of critical anatomic features such as the eyes, cribriform plate region, and caudal extent of the thecal sac are enhanced by this technique. Over a 2-month period, nine consecutive pediatric patients were simulated and planned for craniospinal irradiation. Four patients underwent both conventional simulation and CT simulation. Five were planned using CT simulation only. The accuracy of CT simulation was assessed by comparing digitally reconstructed radiographs (DRRs) to portal films for all patients and to conventional simulation films as well in the first four patients.
RESULTS: Time spent by patients in the CT simulation suite was 20 min on average and 40 min maximally for those who were noncompliant. Image acquisition time was <10 min in all cases. In the absence of the patient, virtual simulation of all fields took 20 min. The DRRs were in agreement with portal and/or simulation films to within 5 mm in five of the eight cases. Discrepancies of > or =5 mm in the positioning of the inferior border of the cranial fields in the first three patients were due to a systematic error in CT scan acquisition and marker contouring which was corrected by modifying the technique after the fourth patient. In one patient, the facial shield had to be moved 0.75 cm inferiorly owing to an error in shield construction.
CONCLUSIONS: Our analysis showed that CT simulation of craniospinal fields was accurate. It resulted in a significant reduction in the time the patient must be immobilized during the planning process. This technique can improve accuracy in field placement and shielding by using three-dimensional CT-aided localization of critical and target structures. Overall, it has improved staff efficiency and resource utilization.

Entities:  

Mesh:

Year:  1998        PMID: 9719108     DOI: 10.1016/s0360-3016(98)00108-4

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  High-precision radiotherapy for craniospinal irradiation: evaluation of three-dimensional conformal radiotherapy, intensity-modulated radiation therapy and helical TomoTherapy.

Authors:  D S Sharma; T Gupta; R Jalali; Z Master; R D Phurailatpam; R Sarin
Journal:  Br J Radiol       Date:  2009-07-06       Impact factor: 3.039

2.  A novel inverse optimization based three-dimensional conformal radiotherapy technique in craniospinal irradiation.

Authors:  Fatih Biltekin; Gozde Yazici; Gokhan Ozyigit
Journal:  Phys Eng Sci Med       Date:  2021-02-08

3.  Performance evaluation of a dedicated computed tomography scanner used for virtual simulation using in-house fabricated CT phantoms.

Authors:  D S Sharma; S D Sharma; K K Sanu; S Saju; D D Deshpande; S Kannan
Journal:  J Med Phys       Date:  2006-01

4.  Method to plan, administer, and verify supine craniospinal irradiation.

Authors:  Jeff M Michalski; Eric E Klein; Russell Gerber
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

5.  Assessment of the results and hematological side effects of 3D conformal and IMRT/ARC therapies delivered during craniospinal irradiation of childhood tumors with a follow-up period of five years.

Authors:  Zoltán Lőcsei; Róbert Farkas; Kornélia Borbásné Farkas; Klára Sebestyén; Zsolt Sebestyén; Zoltán Musch; Ágnes Vojcek; Noémi Benedek; László Mangel; Gábor Ottóffy
Journal:  BMC Cancer       Date:  2020-07-29       Impact factor: 4.430

6.  Practical aspects of the application of helical tomotherapy for craniospinal irradiation.

Authors:  Joongyo Lee; Euidam Kim; Nalee Kim; Hwa Kyung Byun; Chang-Ok Suh; Yoonsun Chung; Hong In Yoon
Journal:  Sci Rep       Date:  2021-03-17       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.