Literature DB >> 9716200

Restenosis rate after intravascular ultrasound-guided coronary stent implantation.

R Blasini1, F J Neumann, C Schmitt, H Walter, A Schömig.   

Abstract

This study was designed to test the hypothesis that patients fulfilling intravascular ultrasound (IVUS) criteria for optimal coronary stent implantation show a reduction in the restenosis rate at 6 months. IVUS guidance for stent dilation may be associated with facilitated stent implantation and an increased acute luminal gain, but it has not yet been determined, whether and to what extent this procedure is associated with a reduction in the restenosis rate. IVUS-guided optimization of Palmaz-Schatz stent placement was performed in 125 consecutive patients, 64 of whom fulfilled IVUS-criteria for optimal stent placement. Another 125 patients served as the non-IVUS control group. In 107 patients (86%) of the non-IVUS control group and 105 patients (84%) of the IVUS group, angiographic follow-up was performed. The IVUS group of patients revealed a significantly lower restenosis rate of 20.9% as compared with 29.9% in the control group (P = 0.033). Patients that met IVUS criteria for optimal stent placement had a larger minimal lumen diameter immediately after stent implantation (3.13 +/- 0.44 vs. 2.95 +/- 0.47 mm; P = 0.045) and at 6-month follow-up (2.23 +/- 0.78 vs. 1.87 +/- 0.76 mm; P = 0.019) as well as a significantly lower restenosis rate (13.5% vs. 28.3%; P = 0.038) as compared with patients that did not fulfil these criteria. Our data suggest that patients fulfilling IVUS criteria for optimal stent placement demonstrate a reduced risk for the development of restenosis. Thus, IVUS investigation identifies factors predictive of restenosis after coronary stent placement.

Entities:  

Mesh:

Year:  1998        PMID: 9716200     DOI: 10.1002/(sici)1097-0304(199808)44:4<380::aid-ccd3>3.0.co;2-0

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  4 in total

1.  Incidence of stent under-deployment as a cause of in-stent restenosis in long stents.

Authors:  Olivier F Bertrand; Robert De Larochellière; Michel Joyal; Raoul Bonan; Rosaire Mongrain; Jean-Claude Tardif
Journal:  Int J Cardiovasc Imaging       Date:  2004-08       Impact factor: 2.357

2.  Intra-coronary imaging modalities.

Authors:  Paul M Johnson; Jigar Patel; Michael Yeung; Prashant Kaul
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-05

Review 3.  Angioplasty guided by intravascular ultrasound: meta-analysis of randomized clinical trials.

Authors:  José Albuquerque de Figueiredo Neto; Iara Antonia Lustosa Nogueira; Mabel Fernandes Figueiro; Anna Maria Buehler; Otavio Berwanger
Journal:  Arq Bras Cardiol       Date:  2013-07-02       Impact factor: 2.000

4.  Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study.

Authors:  A L Gaster; U Slothuus Skjoldborg; J Larsen; L Korsholm; C von Birgelen; S Jensen; P Thayssen; K E Pedersen; T H Haghfelt
Journal:  Heart       Date:  2003-09       Impact factor: 5.994

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.