Incidence of stent under-deployment as a cause of in-stent restenosis in long stents.

Olivier F Bertrand1, Robert De Larochellière, Michel Joyal, Raoul Bonan, Rosaire Mongrain, Jean-Claude Tardif.   

Abstract

Although stent under-deployment (SU) has been associated with increased risk of in-stent restenosis, little data have been reported on the incidence of SU in patients presenting with clinical in-stent restenosis. In 59 patients referred for vascular brachytherapy and showing angiographic in-stent restenosis, we sought (1) to determine the incidence of SU using standard intravascular ultrasound (IVUS) criteria (2) to evaluate the effects of repeat angioplasty on further stent expansion. Stented length was 32+/-17 mm and diameter stenosis was 75+/-14%. Before re-intervention, the incidence of reduced absolute values of minimal stent cross-sectional area (MSCSA) varied from 69% (< or =8 mm2) to 15% (< or =5 mm2). After re-intervention, the incidence decreased to 24% (< or =8 mm2) (p = 0.0001) and 0% (< or =5 mm2) (p = 0.005). Before re-intervention, SU as assessed by relative criteria varied from 21% (80% mean reference lumen area or 90% minimum distal reference lumen area) to 28% (100% minimum reference lumen area). After re-intervention, the incidence of SU varied from 7% (90% minimum distal reference lumen area) (p = 0.0001 vs. pre) to 24% (55% mean reference EEM area) (p = ns). No change in strut apposition (97% pre vs. 100% post) nor in symmetry index (100% pre vs. post) was noted. From all criteria, the 90 and 100% minimum reference lumen area criteria were the most altered by repeat balloon dilatation, 21% pre vs. 7% post and 28% pre vs. 11% post, respectively. In conclusion, among patients presenting with severe angiographic in-stent restenosis, a significant number showed signs of SU whose incidence varied according to applied criteria. Significant stent re-expansion can be obtained following IVUS-guided repeat angioplasty irrespective of initial SU criteria.

Entities:  

Mesh:

Year:  2004        PMID: 15529909     DOI: 10.1023/b:caim.0000041947.11384.93

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  17 in total

1.  Improved outcome using IVUS-guided stent implantation: premise or promise?

Authors:  A Jeremias; R Erbel
Journal:  Catheter Cardiovasc Interv       Date:  1999-10       Impact factor: 2.692

2.  Does the specific intravascular ultrasound criterion used to optimize stent expansion have an impact on the probability of stent restenosis?

Authors:  I Moussa; J Moses; C Di Mario; R Albiero; J De Gregorio; M Adamian; L Di Francesco; A Colombo
Journal:  Am J Cardiol       Date:  1999-04-01       Impact factor: 2.778

3.  Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study.

Authors:  P J Fitzgerald; A Oshima; M Hayase; J A Metz; S R Bailey; D S Baim; M W Cleman; E Deutsch; D J Diver; M B Leon; J W Moses; S N Oesterle; P A Overlie; C J Pepine; R D Safian; J Shani; C A Simonton; R W Smalling; P S Teirstein; J P Zidar; A C Yeung; R E Kuntz; P G Yock
Journal:  Circulation       Date:  2000-08-01       Impact factor: 29.690

4.  An optimal diagnostic threshold for minimal stent area to predict target lesion revascularization following stent implantation in native coronary lesions.

Authors:  Y Morino; Y Honda; H Okura; A Oshima; M Hayase; H N Bonneau; R E Kuntz; P G Yock; P J Fitzgerald
Journal:  Am J Cardiol       Date:  2001-08-01       Impact factor: 2.778

5.  Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis.

Authors:  R Mehran; G S Mintz; J J Popma; A D Pichard; L F Satler; K M Kent; J Griffin; M B Leon
Journal:  Am J Cardiol       Date:  1996-09-15       Impact factor: 2.778

Review 6.  Role of intravascular ultrasound in the evaluation of mechanisms of coronary interventions and restenosis.

Authors:  G Görge; J Ge; R Erbel
Journal:  Am J Cardiol       Date:  1998-06-18       Impact factor: 2.778

7.  Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions.

Authors:  R Albiero; T Rau; M Schlüter; C Di Mario; B Reimers; D G Mathey; J M Tobis; J Schofer; A Colombo
Journal:  Circulation       Date:  1997-11-04       Impact factor: 29.690

8.  Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents.

Authors:  R Hoffmann; G S Mintz; R Mehran; A D Pichard; K M Kent; L F Satler; J J Popma; H Wu; M B Leon
Journal:  J Am Coll Cardiol       Date:  1998-01       Impact factor: 24.094

9.  Optimal deployment of third-generation stents: an intravascular ultrasound assessment.

Authors:  James T Maddux; John D Carroll; Bertron M Groves; John C Messenger; Albert Tseng; Erin Falcone; J E B Burchenal
Journal:  Catheter Cardiovasc Interv       Date:  2002-10       Impact factor: 2.692

10.  Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

Authors:  P de Jaegere; H Mudra; H Figulla; Y Almagor; S Doucet; I Penn; A Colombo; C Hamm; A Bartorelli; M Rothman; M Nobuyoshi; T Yamaguchi; V Voudris; C DiMario; S Makovski; D Hausmann; S Rowe; S Rabinovich; M Sunamura; G A van Es
Journal:  Eur Heart J       Date:  1998-08       Impact factor: 29.983

View more
  3 in total

1.  Incidence of stent under-deployment as a cause of in-stent restenosis in long stents: take your lesson!

Authors:  William Wijns
Journal:  Int J Cardiovasc Imaging       Date:  2004-12       Impact factor: 2.357

2.  Conformability of balloon-expandable stents to the carotid siphon: an in vitro study.

Authors:  R du Mesnil de Rochemont; B Yan; F E Zanella; D A Rüfenacht; J Berkefeld
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

Review 3.  Physiologic Assessment after Coronary Stent Implantation.

Authors:  Doyeon Hwang; Seokhun Yang; Jinlong Zhang; Bon Kwon Koo
Journal:  Korean Circ J       Date:  2021-03       Impact factor: 3.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.