Light and scanning electron microscopic report of four fractured implants.

A Piattelli1, M Piattelli, A Scarano, L Montesani.   

Abstract

Although they are fortunately rare, implant fractures can cause significant problems for both clinicians and patients. The authors present a light and scanning electron microscopic study of four fractured implants in two patients. Both patients had parafunctional habits (bruxism), hypertrophic masticatory muscles, and wear of occlusal surfaces. The scanning electron microscopic study of the fractured surfaces of all four implants showed the presence of fatigue striations. Bending overload was probably created by a combination of parafunctional forces, bone resorption, posterior location of the implants, and implant diameter.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9714964

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

1.  Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study.

Authors:  Sergio Alexandre Gehrke; Miriam Souza Dos Santos Vianna; Berenice Anina Dedavid
Journal:  Clin Oral Investig       Date:  2013-07-17       Impact factor: 3.573

Review 2.  Dental implant fractures - aetiology, treatment and case report.

Authors:  Coelho Goiato Marcelo; Marcela Filié Haddad; Humberto Gennari Filho; Luiz Marcelo Ribeiro Villa; Daniela Micheline Dos Santos; Alves Pesqueira Aldiéris
Journal:  J Clin Diagn Res       Date:  2014-03-15

3.  Effect of loading frequency on cyclic fatigue lifetime of a standard-diameter implant with an internal abutment connection.

Authors:  Yuanyuan Duan; Jason A Griggs
Journal:  Dent Mater       Date:  2018-09-13       Impact factor: 5.304

Review 4.  A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia.

Authors:  Reham B Osman; Michael V Swain
Journal:  Materials (Basel)       Date:  2015-03-05       Impact factor: 3.623

5.  Retrospective evaluation of perioperative and short term clinical outcomes in appendicular long bone skeleton fractures repaired via the string of pearls (SOP) locking plate system.

Authors:  Matthew R Field; Ryan Butler; Robert W Wills; Wilburn M Maxwell
Journal:  BMC Vet Res       Date:  2018-12-05       Impact factor: 2.741

6.  Noninvasive method for retrieval of broken dental implant abutment screw.

Authors:  Jagadish Reddy Gooty; Sunil Kumar Palakuru; Vikram Reddy Guntakalla; Mahipal Nera
Journal:  Contemp Clin Dent       Date:  2014-04

Review 7.  Implant fractures: Rare but not exceptional.

Authors:  Sahitya Sanivarapu; Srinivas Moogla; Rupa Sruthi Kuntcham; Lakshmi Kanth Kolaparthy
Journal:  J Indian Soc Periodontol       Date:  2016 Jan-Feb
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.