Literature DB >> 9714956

A comparative clinical study of three different endosseous implants in edentulous mandibles.

A K Røynesdal1, E Ambjørnsen, S Støvne, H R Haanaes.   

Abstract

The purpose of this prospective study was to investigate the clinical outcome and marginal bone resorption of three different endosseous implants placed in the anterior mandibles of 15 elderly patients. Eleven women and 4 men (ranging from 65 to 80 years, mean 71 years) had three different endosseous implants placed in the anterior mandible; one titanium plasma-sprayed cylinder implant (4-mm diameter), one titanium cylinder implant with hydroxyapatite coating (4-mm diameter), and one standard threaded titanium implant (3.75-mm diameter). Three months later, at the second-stage surgical procedure, ball abutments were connected and an overdenture was placed. At 12, 24, and 36 months, marginal bone resorption and Periotest values were recorded. None of the implants was lost in this period. An analysis of variance with repeated measurement was performed annually to test the existence of significant differences between the implants. When differences appeared, paired t tests were used to identify which differences were significant. Bonferroni multipliers were used to adjust for multiple testing. When marginal bone resorption was concerned, threaded titanium and hydroxyapatite-coated implants had significantly better scores than titanium plasma-sprayed cylinder implants. Periotest values for hydroxyapatite-coated implants were significantly better than test values for the other implants after 2 years. After 3 years significance was obtained between hydroxyapatite and screw-shaped implants only (P < .05). It was concluded that titanium plasma-sprayed cylinder implants have a less favorable prognosis than the other implants used in this study.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9714956

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

1.  Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws.

Authors:  M Cimerman; A Cör; M Ceh; A Kristan; J Pizem; M Tonin
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

2.  Study of Biomechanics of Porous Coated Root Form Implant Using Overdenture Attachment: A 3D FEA.

Authors:  Ravindra C Savadi; Chhavi Goyal
Journal:  J Indian Prosthodont Soc       Date:  2011-02-01

3.  Osteoblast proliferation and maturation on bioactive fiber-reinforced composite surface.

Authors:  Ahmed Mansour Ballo; Anne K Kokkari; Ville V Meretoja; Lippo L Lassila; Pekka K Vallittu; Timo O Narhi
Journal:  J Mater Sci Mater Med       Date:  2008-04-25       Impact factor: 3.896

4.  Fortifying the Bone-Implant Interface Part 1: An In Vitro Evaluation of 3D-Printed and TPS Porous Surfaces.

Authors:  Regina F MacBarb; Derek P Lindsey; Chelsea S Bahney; Shane A Woods; Mark L Wolfe; Scott A Yerby
Journal:  Int J Spine Surg       Date:  2017-06-01

5.  Gene expression of MC3T3-E1 osteoblastic cells on titanium and zirconia surface.

Authors:  Soon-Hyun Gong; Heesu Lee; Ahran Pae; Kwantae Noh; Yong-Moon Shin; Jung-Haeng Lee; Yi-Hyung Woo
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

6.  Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study.

Authors:  Soumyadev Satpathy; C L Satish Babu; Shilpa Shetty; Bharat Raj
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

Review 7.  Bioactive Glass and Silicate-Based Ceramic Coatings on Metallic Implants: Open Challenge or Outdated Topic?

Authors:  Giulia Brunello; Hamada Elsayed; Lisa Biasetto
Journal:  Materials (Basel)       Date:  2019-09-10       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.