Two patients are reported who had tendon rupture and plate breakage following internal fixation with the newly designed AO/ASIF titanium distal radius plate system (pi plate). The incidence of complications with this system warrants further evaluation.

Entities:  

Mesh:

Year:  1998        PMID: 9708391     DOI: 10.1016/S0363-5023(98)80063-4

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  28 in total

1.  The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures.

Authors:  Lucile Vaiss; Satoshi Ichihara; Sarah Hendriks; Chihab Taleb; Philippe Liverneaux; Sybille Facca
Journal:  J Wrist Surg       Date:  2014-11

2.  [Results of palmar T-plate osteosynthesis in unstable fractures of the distal radius].

Authors:  C Dumont; M Fuchs; E K Folwaczny; C Heuermann; K M Stürmer
Journal:  Chirurg       Date:  2003-09       Impact factor: 0.955

Review 3.  [Is routine implant removal after trauma surgery sensible?].

Authors:  C Krettek; C Müller; R Meller; M Jagodzinski; F Hildebrand; R Gaulke
Journal:  Unfallchirurg       Date:  2012-04       Impact factor: 1.000

4.  Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating.

Authors:  Kagan Ozer; Serdar Toker
Journal:  Hand (N Y)       Date:  2011-01-07

5.  Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study.

Authors:  Steven D Maschke; Peter J Evans; David Schub; Richard Drake; Jeffrey N Lawton
Journal:  Hand (N Y)       Date:  2007-04-26

6.  Complex fractures of the distal radius treated with angular stability plates.

Authors:  Marco Frattini; Giovanni Soncini; Maurizio Corradi; Bruno Panno; Silvio Tocco; Francesco Pogliacomi
Journal:  Chir Organi Mov       Date:  2009-07-21

7.  Internal versus external fixation for unstable distal radius fractures: an up-to-date meta-analysis.

Authors:  Zhuang Cui; Jianhong Pan; Bin Yu; Kairui Zhang; Xiaolong Xiong
Journal:  Int Orthop       Date:  2011-06-23       Impact factor: 3.075

8.  Volar locking plate fixation of distal radius fractures: use of an intra-operative 'carpal shoot through' view to identify dorsal compartment and distal radioulnar joint screw penetration.

Authors:  Daniel Marsland; Chris M Hobbs; Philip S Sauvé
Journal:  Hand (N Y)       Date:  2014-12

9.  [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

Authors:  M Hakimi; P Jungbluth; S Gehrmann; J Nowak; J Windolf; M Wild
Journal:  Unfallchirurg       Date:  2010-03       Impact factor: 1.000

10.  Different osteosyntheses for Colles' fracture: a mechanical study in 42 cadaver bones.

Authors:  Yngvar Krukhaug; Nils R Gjerdet; Odd J Lundberg; Peer K Lilleng; Leiv M Hove
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.