Literature DB >> 9703053

Nitroxide free radical clearance in the live rat monitored by radio-frequency CW-EPR and PEDRI.

M Alecci1, I Seimenis, S J McCallum, D J Lurie, M A Foster.   

Abstract

The use of RF (100 to 300 MHz) PEDRI and CW-EPR techniques allows the in vivo study of large animals such as whole rats and rabbits. Recently a PEDRI instrument was modified to also allow CW-EPR spectroscopy with samples of similar size and under the same experimental conditions. In the present study, this CW-EPR and PEDRI apparatus was used to assess the feasibility of the detection of a pyrrolidine nitroxide free radical (2,2,5,5,-tetramethylpyrrolidine-1-oxyl-3-carboxylic acid, PCA) in the abdomen of rats. In particular, we have shown that after the PCA administration (4 mmol kg(-1) b.w.): (i) the PCA EPR linewidth does not show line broadening due to concentration effects; (ii) a similar PCA up-take phase is observed by EPR and PEDRI; and (iii) the PCA half-lives in the whole abdomen of rats measured with the CW-EPR (T1/2=26+/-4 min, mean+/-sd, n=10) and PEDRI (T1/2=29+/-4 min, mean+/-sd, n=4) techniques were not significantly different (p > 0.05). These results show, for the first time, that information about PCA pharmacokinetics obtained by CW-EPR is the same as that from PEDRI under the same experimental conditions.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9703053     DOI: 10.1088/0031-9155/43/7/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Single loop multi-gap resonator for whole body EPR imaging of mice at 1.2 GHz.

Authors:  Sergey Petryakov; Alexandre Samouilov; Eric Kesselring; Tomasz Wasowicz; George L Caia; Jay L Zweier
Journal:  J Magn Reson       Date:  2007-06-09       Impact factor: 2.229

Review 2.  Oxidative stress imaging in live animals with techniques based on electron paramagnetic resonance.

Authors:  Martyna Elas; Kazuhiro Ichikawa; Howard J Halpern
Journal:  Radiat Res       Date:  2012-02-21       Impact factor: 2.841

3.  A loop resonator for slice-selective in vivo EPR imaging in rats.

Authors:  Hiroshi Hirata; Guanglong He; Yuanmu Deng; Ildar Salikhov; Sergey Petryakov; Jay L Zweier
Journal:  J Magn Reson       Date:  2007-10-30       Impact factor: 2.229

4.  Development of an L-band resonator optimized for fast scan EPR imaging of the mouse head.

Authors:  Alexandre Samouilov; Denis Komarov; Sergey Petryakov; Arkadiy Iosilevich; Jay L Zweier
Journal:  Magn Reson Med       Date:  2021-05-03       Impact factor: 3.737

5.  Noninvasive Diagnosis of the Mitochondrial Function of Doxorubicin-Induced Cardiomyopathy Using In Vivo Dynamic Nuclear Polarization-Magnetic Resonance Imaging.

Authors:  Yukie Mizuta; Tomohiko Akahoshi; Hinako Eto; Fuminori Hyodo; Masaharu Murata; Kentaro Tokuda; Masatoshi Eto; Ken Yamaura
Journal:  Antioxidants (Basel)       Date:  2022-07-26
  5 in total