Literature DB >> 9694445

Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition.

J Golzarian1, L Dussaussois, H T Abada, P A Gevenois, D Van Gansbeke, J Ferreira, J Struyven.   

Abstract

OBJECTIVE: We report our prospective study evaluating biphasic helical CT of the aorta after endoluminal stent-graft placement. SUBJECTS AND METHODS: Biphasic helical CT scans in 95 patients with abdominal and thoracic aortic aneurysms who had undergone endoluminal stent-graft placement were reviewed. After a test bolus injection of 15 ml of contrast media at a rate of 3.5 ml/sec for the measurement of the optimal start delay, the aorta was scanned using the following parameters: collimation of 5 mm, table speed of 7 mm per rotation, tube rotation time of 0.75 sec, 120 kV, and 295 mA. A delayed helical CT scan was obtained 15 sec after the initial acquisition using the same parameters.
RESULTS: Biphasic helical CT scans showed perigraft leakage in 45 (47%) of 95 patients. Leakage was shown only on arterial phase CT in eight patients and only on the delayed scans in three patients. In two patients, leakage shown on the delayed acquisition was retrospectively seen on the first scan. Leakage and outflow vessels were most visible on the arterial phase acquisition in 17 patients and on the second acquisition in six patients. Overall, biphasic acquisition was superior to arterial phase acquisition alone in 15 (16%) of 95 patients.
CONCLUSION: The diagnostic value of biphasic helical CT is superior to arterial phase acquisition alone for the evaluation of the aorta after endoluminal stent-graft therapy.

Entities:  

Mesh:

Year:  1998        PMID: 9694445     DOI: 10.2214/ajr.171.2.9694445

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  17 in total

Review 1.  Current concepts in the evaluation of vascular disease: magnetic resonance and computed tomographic angiography.

Authors:  B D Toombs; J M Jing
Journal:  Tex Heart Inst J       Date:  2000

2.  Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

Authors:  Stefanie Weigel; Bernd Tombach; David Maintz; Stefan Klotz; Thomas Vestring; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

Review 3.  Endoleakage after endovascular treatment of abdominal aortic aneurysms: Diagnosis, significance and treatment.

Authors:  Jafar Golzarian; David Valenti
Journal:  Eur Radiol       Date:  2006-04-11       Impact factor: 5.315

4.  [Ultrasound imaging of the abdominal aorta].

Authors:  D-A Clevert; A Horng; M F Reiser
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

5.  [Imaging of endoleaks after endovascular aneurysm repair (EVAR) with contrast-enhanced ultrasound (CEUS)].

Authors:  D-A Clevert; A Horng; R Kopp; K Schick; G Meimarakis; W H Sommer; M Reiser
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

Review 6.  CT angiography after 20 years: a transformation in cardiovascular disease characterization continues to advance.

Authors:  Geoffrey D Rubin; Jonathon Leipsic; U Joseph Schoepf; Dominik Fleischmann; Sandy Napel
Journal:  Radiology       Date:  2014-06       Impact factor: 11.105

Review 7.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Authors:  Evridiki Karanikola; Ilias Dalainas; Georgios Karaolanis; Georgios Zografos; Konstantinos Filis
Journal:  Int J Angiol       Date:  2014-09

8.  Imaging of aortic abnormalities with contrast-enhanced ultrasound. A pictorial comparison with CT.

Authors:  D-A Clevert; M Stickel; T Johnson; C Glaser; D-A Clevert; H O Steitz; R Kopp; K W Jauch; M Reiser
Journal:  Eur Radiol       Date:  2007-01-12       Impact factor: 5.315

9.  Clinical significance of endoleaks characterized by computed tomography during aortography performed immediately after endovascular abdominal aortic aneurysm repair: prediction of persistent endoleak.

Authors:  Motoki Nakai; Hirotatsu Sato; Morio Sato; Yuko Tanba; Yasutaka Noda; Akira Ikoma; Hiroki Sanda; Kohei Nakata; Hiroki Minamiguchi; Nobuyuki Kawai; Tetsuo Sonomura; Kazushi Kishi; Yosiharu Nishimura; Yoshitaka Okamura
Journal:  Jpn J Radiol       Date:  2012-10-10       Impact factor: 2.374

10.  Hybrid-repair of thoraco-abdominal or juxtarenal aortic aneurysm: what the radiologist should know.

Authors:  Tobias Krauss; Thomas Pfammatter; Dieter Mayer; Mario Lachat; Lukas Hechelhammer; Borut Marincek; Thomas Frauenfelder
Journal:  Eur Radiol       Date:  2009-09-30       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.