Literature DB >> 9674010

Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens.

O Nishi1, K Nishi, K Sakanishi.   

Abstract

BACKGROUND AND
OBJECTIVE: To study the mechanism of the reportedly low incidence of posterior capsule opacification (PCO) in eyes treated with a posterior chamber intraocular lens (PC IOL).
MATERIALS AND METHODS: Various IOL designs, including the PC IOL, were studied using scanning electron microscopy. Rabbit lens capsules were studied histopathologically 2, 3, and 4 weeks after implantation of a PC IOL in one eye and a biconvex polymethylmethacrylate (PMMA) IOL in the contralateral eye as a control.
RESULTS: The optic edge of the PC IOL was sharp and rectangular, whereas that of the biconvex PMMA or silicone IOLs from various manufacturers had been smoothed and rounded by polishing. PCO was significantly reduced in the eye with a PC IOL in all rabbits. The lens capsule wrapped tightly around the optic edge of the PC IOL so that it conformed to the same shape and thereby created a distinct rectangular bend in the capsule or a rectangle between the optic edge and the posterior capsule. Migrating lens epithelial cells (LECs) were obviously inhibited at that site.
CONCLUSIONS: A discontinuous capsular bend or rectangle created by the sharp, square optic edge of the PC IOL may have induced contact inhibition to migrating LECs and reduced PCO. How, whether, and to what extent this design-dependent effect is influenced by features of the IOL material needs to be clarified by comparison with results achieved with an IOL made from the same material in a different design and vice versa.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9674010

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers        ISSN: 1082-3069


  30 in total

Review 1.  Management of cataract surgery in a high myope.

Authors:  H Seward; R Packard; D Allen
Journal:  Br J Ophthalmol       Date:  2001-11       Impact factor: 4.638

Review 2.  [New methods for the prevention of posterior capsule opacification].

Authors:  G U Auffarth; T M Rabsilber; A J Reuland
Journal:  Ophthalmologe       Date:  2005-06       Impact factor: 1.059

3.  Prospective, non-randomised, long term clinical evaluation of a foldable hydrophilic single piece intraocular lens: results of the Centerflex FDA study.

Authors:  K A Becker; M Martin; T M Rabsilber; B B Entz; A J Reuland; G U Auffarth
Journal:  Br J Ophthalmol       Date:  2006-05-10       Impact factor: 4.638

4.  [Secondary increase in intraocular pressure after complication-free cataract operation with implantation of the posterior chamber lens].

Authors:  D Kook; T Kohnen
Journal:  Ophthalmologe       Date:  2009-02       Impact factor: 1.059

5.  Effect of four different intraocular lenses on posterior capsule opacification.

Authors:  Rahmi Duman; Fatih Karel; Pelin Özyol; Can Ateş
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

6.  Evaluation of a human capsular bag model for secondary cataract determination after intraocular lens implantation.

Authors:  A Liekfeld; N Pahms; N Torun; A U Porstmann; J Jaroszewski; C Hartmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-09-10       Impact factor: 3.117

7.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

8.  Findings of an experimental study in a rabbit model on posterior capsule opacification after implantation of hydrophobic acrylic and hydrophilic acrylic intraocular lenses.

Authors:  Nikolaos Trakos; Elli Ioachim; Elena Tsanou; Miltiadis Aspiotis; Konstantinos Psilas; Chris Kalogeropoulos
Journal:  Clin Ophthalmol       Date:  2008-12

9.  A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.

Authors:  R Nejima; K Miyata; M Honbou; T Tokunaga; T Tanabe; M Sato; T Oshika
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

10.  Retinal phototoxicity in a novel murine model of intraocular lens implantation.

Authors:  Toshihide Kurihara; Masahiro Omoto; Kousuke Noda; Mari Ebinuma; Shunsuke Kubota; Haruna Koizumi; Satoru Yoshida; Yoko Ozawa; Shigeto Shimmura; Susumu Ishida; Kazuo Tsubota
Journal:  Mol Vis       Date:  2009-12-12       Impact factor: 2.367

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.