Literature DB >> 9671925

Surface stiffness affects impact force during a fall on the outstretched hand.

S N Robinovitch1, J Chiu.   

Abstract

Falls on the outstretched hand are among the most common causes of traumatic bone fracture. However, little is known regarding the biomechanical factors that affect the risk for injury during these events. In the present study, we explored how upper-extremity impact forces during forward falls are affected by modification of surface stiffness, an intervention applicable to high-risk environments such as nursing homes, playgrounds, and gymnasiums. Results from both experimental and linear biomechanical models suggest that during a fall onto an infinitely stiff surface, hand contact force is governed by a high-frequency transient (having an associated peak force Fmax1), followed by a low-frequency oscillation (having an associated lower magnitude peak force Fmax2). Practical decreases in surface stiffness attenuate Fmax1 but not Fmax2 or the magnitude of force transmitted to the shoulder. Model simulations reveal that this arises from the compliant surface's ability to decrease the velocity across the wrist damping elements at the moment of impact (which governs Fmax1) but inability to substantially reduce the peak deflection of the shoulder spring (which governs Fmax2). Comparison between model predictions and previous data on fracture force suggests that feasible compliant surface designs may prevent wrist injuries during falls from standing height or lower, because Fmax1 will be attenuated and Fmax2 will remain below injurious levels. However, such surfaces cannot prevent Fmax2 from exceeding injurious levels during falls from greater heights and therefore likely provide little protection against upper-extremity injuries in these cases.

Entities:  

Mesh:

Year:  1998        PMID: 9671925     DOI: 10.1002/jor.1100160306

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  13 in total

Review 1.  Playground injuries to children.

Authors:  C Norton; J Nixon; J R Sibert
Journal:  Arch Dis Child       Date:  2004-02       Impact factor: 3.791

2.  Age-dependent variations in the directional sensitivity of balance corrections and compensatory arm movements in man.

Authors:  J H J Allum; M G Carpenter; F Honegger; A L Adkin; B R Bloem
Journal:  J Physiol       Date:  2002-07-15       Impact factor: 5.182

3.  Pressure distribution over the palm region during forward falls on the outstretched hands.

Authors:  W J Choi; S N Robinovitch
Journal:  J Biomech       Date:  2010-10-28       Impact factor: 2.712

4.  The potential for brain injury on selected surfaces used by cheerleaders.

Authors:  Brenda J Shields; Gary A Smith
Journal:  J Athl Train       Date:  2009 Nov-Dec       Impact factor: 2.860

5.  Shock-absorbing effects of various padding conditions in improving efficacy of wrist guards.

Authors:  Il-Kyu Hwang; Kyu-Jung Kim
Journal:  J Sports Sci Med       Date:  2004-03-01       Impact factor: 2.988

6.  Out on a limb: risk factors for arm fracture in playground equipment falls.

Authors:  S Sherker; J Ozanne-Smith; G Rechnitzer; R Grzebieta
Journal:  Inj Prev       Date:  2005-04       Impact factor: 2.399

7.  Age-related changes in protective arm reaction kinematics, kinetics, and neuromuscular activation during evoked forward falls.

Authors:  James Borrelli; Robert Creath; Kelly Westlake; Mark W Rogers
Journal:  Hum Mov Sci       Date:  2021-12-16       Impact factor: 2.161

8.  Age differences in energy absorption in the upper extremity during a descent movement: implications for arresting a fall.

Authors:  Meena M Sran; Paula J Stotz; Sarah C Normandin; Stephen N Robinovitch
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2009-10-27       Impact factor: 6.053

9.  Falls: epidemiology, pathophysiology, and relationship to fracture.

Authors:  Sarah D Berry; Ram R Miller
Journal:  Curr Osteoporos Rep       Date:  2008-12       Impact factor: 5.096

10.  Off-axis loads cause failure of the distal radius at lower magnitudes than axial loads: a finite element analysis.

Authors:  Karen L Troy; Mark D Grabiner
Journal:  J Biomech       Date:  2007-03-26       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.