Literature DB >> 21035120

Pressure distribution over the palm region during forward falls on the outstretched hands.

W J Choi1, S N Robinovitch.   

Abstract

Falls on the outstretched hands are the cause of over 90% of wrist fractures, yet little is known about bone loading during this event. We tested how the magnitude and distribution of pressure over the palm region during a forward fall is affected by foam padding (simulating a glove) and arm configuration, and by the faller's body mass index (BMI) and thickness of soft tissues over the palm region. Thirteen young women with high (n=7) or low (n=6) BMI participated in a "torso release experiment" that simulated falling on both outstretched hands with the arm inclined either at 20° or 40° from the vertical. Trials were acquired with and without a 5 mm thick foam pad secured to the palm. Outcome variables were the magnitude and location of peak pressure (d, θ) with respect to the scaphoid, total impact force, and integrated force applied to three concentric areas, including "danger zone" of 2.5 cm radius centered at the scaphoid. Soft tissue thickness over the palm was measured by ultrasound. The 5mm foam pad reduced peak pressure, and peak force to the danger zone, by 83% and 13%, respectively. Peak pressure was 77% higher in high BMI when compared with low BMI participants. Soft tissue thickness over the palm correlated positively with distance (d) (R=0.79, p=0.001) and force applied outside the danger zone (R=0.76, p=0.002), but did not correlate with BMI (R=0.43, p=0.14). The location of peak pressure was shunted 4 mm further from the scaphoid at 20° than that of 40° falls (d=25 mm (SD 8), θ=-9° (SD 17) in the 20° falls versus d=21 mm (SD 8), θ=-5° (SD 24) in the 40° falls). Peak force to the entire palm was 11% greater in 20° compared with 40° falls. These results indicate that even a 5 mm thick foam layer protects against wrist injury, by attenuating peak pressure over the palm during forward falls. Increased soft tissue thickness shunts force away from the scaphoid. However, soft tissue thickness is not predicted by BMI, and peak pressures are greater in high individuals than that of low BMI individuals. These results contribute to our understanding of the mechanics and prevention of wrist and hand injuries during falls.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21035120      PMCID: PMC3471983          DOI: 10.1016/j.jbiomech.2010.09.011

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  25 in total

1.  Fall arrest strategy affects peak hand impact force in a forward fall.

Authors:  K M DeGoede; J A Ashton-Miller
Journal:  J Biomech       Date:  2002-06       Impact factor: 2.712

2.  Upper extremity injuries in snowboarding and skiing: a comparative study.

Authors:  Kazu Matsumoto; Kei Miyamoto; Hiroshi Sumi; Yasuhiko Sumi; Katsuji Shimizu
Journal:  Clin J Sport Med       Date:  2002-11       Impact factor: 3.638

3.  [Biomechanical examinations of the efficacy of wrist guards in inline skating].

Authors:  I Müller; M Vogiatzis; K Wiese; S Sönnichsen; T Zantop; K Oehlert; W Petersen; J Hassenpflug
Journal:  Sportverletz Sportschaden       Date:  2003-06       Impact factor: 1.077

4.  On reducing hand impact force in forward falls: results of a brief intervention in young males.

Authors:  J Lo; G N McCabe; K M DeGoede; H Okuizumi; J A Ashton-Miller
Journal:  Clin Biomech (Bristol, Avon)       Date:  2003-10       Impact factor: 2.063

5.  Occurrence of fractures in a defined population: a 1-year study.

Authors:  Y Sahlin
Journal:  Injury       Date:  1990-05       Impact factor: 2.586

6.  In-line skating injuries, 1987 through 1992.

Authors:  S C Callé
Journal:  Am J Public Health       Date:  1994-04       Impact factor: 9.308

7.  Incidence of distal forearm fracture in British men and women.

Authors:  T W O'Neill; C Cooper; J D Finn; M Lunt; D Purdie; D M Reid; R Rowe; A D Woolf; W A Wallace
Journal:  Osteoporos Int       Date:  2001       Impact factor: 4.507

8.  Correlations between photon absorption properties and failure load of the distal radius in vitro.

Authors:  E R Myers; E A Sebeny; A T Hecker; T A Corcoran; J A Hipp; S L Greenspan; W C Hayes
Journal:  Calcif Tissue Int       Date:  1991-10       Impact factor: 4.333

9.  Force attenuation in trochanteric soft tissues during impact from a fall.

Authors:  S N Robinovitch; T A McMahon; W C Hayes
Journal:  J Orthop Res       Date:  1995-11       Impact factor: 3.494

10.  A 10-year study of snowboard injuries in Lapland Sweden.

Authors:  C Made; L-G Elmqvist
Journal:  Scand J Med Sci Sports       Date:  2004-04       Impact factor: 4.221

View more
  5 in total

1.  Effects of hip abductor muscle forces and knee boundary conditions on femoral neck stresses during simulated falls.

Authors:  W J Choi; P A Cripton; S N Robinovitch
Journal:  Osteoporos Int       Date:  2014-07-16       Impact factor: 4.507

2.  A self-cleaning, mechanically robust membrane for minimizing the foreign body reaction: towards extending the lifetime of sub-Q glucose biosensors.

Authors:  A Kristen Means; Ping Dong; Fred J Clubb; Molly C Friedemann; Lydia E Colvin; Courtney A Shrode; Gerard L Coté; Melissa A Grunlan
Journal:  J Mater Sci Mater Med       Date:  2019-06-25       Impact factor: 3.896

3.  Analysis of the Contact Area for Three Types of Upper Limb Strikes.

Authors:  Vaclav Beranek; Petr Stastny; Frederic Turquier; Vit Novacek; Petr Votapek
Journal:  J Funct Morphol Kinesiol       Date:  2022-06-17

4.  Test-retest reliability of the FALL FIT system for assessing and training protective arm reactions in response to a forward fall.

Authors:  James Borrelli; Robert Creath; Kelly Westlake; Mark W Rogers
Journal:  MethodsX       Date:  2022-04-16

5.  In vivo soft tissue compressive properties of the human hand.

Authors:  Victoria Spartacus; Maedeh Shojaeizadeh; Vincent Raffault; James Shoults; Ken Van Wieren; Carolyn J Sparrey
Journal:  PLoS One       Date:  2021-12-13       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.