Literature DB >> 9668704

Sensitivity of routine ultrasound screening of pregnancies in the Eurofetus database. The Eurofetus Team.

H Grandjean1, D Larroque, S Levi.   

Abstract

In this prospective study, we recorded details on 3,685 fetuses with congenital structural abnormalities from an unselected population of women who underwent routine ultrasound examinations during their pregnancies. Overall, 2,262 fetuses were diagnosed as being abnormal before birth (sensitivity = 61.4%). The total number of abnormalities was 4,615, of which 1,733 (37.5%) were major abnormalities. The overall number of detected abnormalities was 2,593 (sensitivity = 56.2%). If only major abnormalities were considered, the sensitivity rose to 73.7%, compared to only 45.7% for the minor abnormalities. Within each severity group, the accuracy of detection varied across systems. For the major abnormalities, it was higher for the central nervous system (88.3%) and urinary tract (84.8%), but lower for heart and great vessels (38.8%). Detection of minor abnormalities was also effective for the urinary tract (89.1%), but not for the heart and great vessels (20.8%) and the musculoskeletal system (18%).

Entities:  

Mesh:

Year:  1998        PMID: 9668704     DOI: 10.1111/j.1749-6632.1998.tb08932.x

Source DB:  PubMed          Journal:  Ann N Y Acad Sci        ISSN: 0077-8923            Impact factor:   5.691


  7 in total

Review 1.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

Review 2.  A translational approach to congenital non-obstructive hydronephrosis.

Authors:  Robyn P Thom; Norman D Rosenblum
Journal:  Pediatr Nephrol       Date:  2012-10-05       Impact factor: 3.714

Review 3.  Current State of Fetal Intervention for Lower Urinary Tract Obstruction.

Authors:  Douglass B Clayton; John W Brock
Journal:  Curr Urol Rep       Date:  2018-02-22       Impact factor: 3.092

4.  Does the Use of Diagnostic Technology Reduce Fetal Mortality?

Authors:  Jostein Grytten; Irene Skau; Rune Sørensen; Anne Eskild
Journal:  Health Serv Res       Date:  2018-01-19       Impact factor: 3.402

5.  Breech presentation at delivery: a marker for congenital anomaly?

Authors:  D Mostello; J J Chang; F Bai; J Wang; C Guild; K Stamps; T L Leet
Journal:  J Perinatol       Date:  2013-10-24       Impact factor: 2.521

6.  Audit of level II scans in a tertiary center of a middle-income country (MIC).

Authors:  Ross Benjamin; Yenuberi Hilda; Rathore Swati; Prasanthi Annie; Beck Manisha; E Mathews Jiji
Journal:  J Family Med Prim Care       Date:  2020-07-30

7.  Trends in fetal indications for termination of pregnancy between 2002 and 2010 at a tertiary referral centre.

Authors:  Aytül Corbacıoğlu; Halil Aslan; Serdar Aydın; Ozgür Akbayır; Fırat Ersan; Verda Alpay; Hediye Dağdeviren; Songül Kısacık
Journal:  J Turk Ger Gynecol Assoc       Date:  2012-06-01
  7 in total