Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patients.

O Gödje1, M Peyerl, T Seebauer, P Lamm, H Mair, B Reichart.   

Abstract

OBJECTIVE: Monitoring of cardiac preload is mainly performed by measurement of central venous and pulmonary capillary wedge pressure in combination with assessment of cardiac output, applying the pulmonary arterial thermal dilution technique. However, the filling pressures are negatively influenced by mechanical ventilation and the pulmonary artery catheter is criticized because of its inherent risks. Measurement of right atria, right ventricular, global end diastolic and intrathoracic blood volume index by arterial thermal dye dilution utilizing the COLD-system may represent an alternative.
METHODS: In 30 CABG patients with an uncomplicated postoperative course the mentioned parameters were measured 1, 3, 6, 12 and 24 h postoperatively to prove their qualification as preload indicators: As patients received no inotropic support, changes of cardiac index and stroke volume index must correlate to changes of presumably preload indicating parameters.
RESULTS: When arterial and pulmonary arterial thermal dilution were compared, no differences were found; the correlation coefficient being 0.96, the bias 0.16 l/min per m2 (2.4%) and coefficients of variation did not exceed 7%. Changes of central venous pressure, capillary wedge pressure, right atrial end diastolic volume index and right ventricular end diastolic volume index did not correlate at all to changes of cardiac and stroke volume index (coefficients ranged from -0.01 to 0.28). In contrast, intrathoracic and global end diastolic blood volume indices with coefficients from 0.76 to 0.87, did show a good correlation to cardiac and stroke volume index.
CONCLUSION: Central venous pressure, capillary wedge pressure, right atrial and right ventricular end diastolic volumes are no suitable preload parameters in cardiac surgery intensive care, compared to intrathoracic and global end diastolic blood volumes. The latter show a higher clinical value and can be obtained by less invasive methods, as no pulmonary artery catheter is required.

Entities:  

Mesh:

Year:  1998        PMID: 9663534     DOI: 10.1016/s1010-7940(98)00063-3

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  40 in total

1.  Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods.

Authors:  Gennady Galstyan; Mychaylo Bychinin; Mikael Alexanyan; Vladimir Gorodetsky
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

2.  Transpulmonary thermodilution in neonates undergoing arterial switch surgery.

Authors:  Andrea Székely; Tamás Breuer; Erzsébet Sápi; Edgár Székely; András Szatmári; Miklós Tóth; Balázs Hauser; János Gál
Journal:  Pediatr Cardiol       Date:  2011-02       Impact factor: 1.655

3.  Methods of monitoring shock.

Authors:  Ednan K Bajwa; Atul Malhotra; B Taylor Thompson
Journal:  Semin Respir Crit Care Med       Date:  2004-12       Impact factor: 3.119

4.  Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery.

Authors:  Joanne Verheij; Arthur van Lingen; Albertus Beishuizen; Herman M T Christiaans; Jan R de Jong; Armand R J Girbes; Willem Wisselink; Jan A Rauwerda; Marinus A J M Huybregts; A B Johan Groeneveld
Journal:  Intensive Care Med       Date:  2006-05-23       Impact factor: 17.440

Review 5.  A definition of normovolaemia and consequences for cardiovascular control during orthostatic and environmental stress.

Authors:  Jasper Truijen; Morten Bundgaard-Nielsen; Johannes J van Lieshout
Journal:  Eur J Appl Physiol       Date:  2010-01-07       Impact factor: 3.078

6.  Influence of extravascular lung water on transpulmonary thermodilution-derived cardiac output measurement.

Authors:  Thomas Pohl; Jan Kozieras; Samir G Sakka
Journal:  Intensive Care Med       Date:  2007-11-03       Impact factor: 17.440

7.  Corrected right ventricular end-diastolic volume and initial distribution volume of glucose correlate with cardiac output after cardiac surgery.

Authors:  Junichi Saito; Hironori Ishihara; Eiji Hashiba; Hirobumi Okawa; Tomoyuki Kudo; Masahiro Sawada; Toshihito Tsubo; Kazuyoshi Hirota
Journal:  J Anesth       Date:  2013-03-02       Impact factor: 2.078

8.  Initial distribution volume of glucose as noninvasive indicator of cardiac preload: comparison with intrathoracic blood volume.

Authors:  Vincenzo Gabbanelli; Simona Pantanetti; Abele Donati; Alessandra Montozzi; Cristiana Carbini; Paolo Pelaia
Journal:  Intensive Care Med       Date:  2004-09-21       Impact factor: 17.440

Review 9.  [Diagnosis and therapy of sepsis. Guidelines of the German Sepsis Society Inc. and the German Interdisciplinary Society for Intensive and Emergency Medicine].

Authors:  K Reinhart; F Brunkhorst; H Bone; H Gerlach; M Gründling; G Kreymann; P Kujath; G Marggraf; K Mayer; A Meier-Hellmann; C Peckelsen; C Putensen; M Quintel; M Ragaller; R Rossaint; F Stüber; N Weiler; T Welte; K Werdan
Journal:  Internist (Berl)       Date:  2006-04       Impact factor: 0.743

Review 10.  Clinical review: Goal-directed therapy in high risk surgical patients.

Authors:  Nicholas Lees; Mark Hamilton; Andrew Rhodes
Journal:  Crit Care       Date:  2009-10-26       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.